80
SWEep Subsystem
<Command>
:SWEep:TYPE {FREQuency|VAC|IAC}
:SWEep:TYPE?
Function
:
It sets or queries the TYPE.
Description
:
Set parameterFREQuency | VAC(voltage) |IAC(current)
Set syntax :SWEep:TYPE FREQuency
Query syntax:LIST:RETest?
Return dataFREQ | VAC | IAC (Format is in <disc>)
<Command>
:SWEep:XAXis {LOGarithm|LINear}
:SWEep:XAXis?
Function
:
It sets or queries the XAXIS.
Description
:
Set parameterLOGarithm | LINear
Set syntax:SWEep:XAXis LOGarithm
Query syntax:SWEep:XAXis?
Return dataLOG | LIN (Format is in <disc>)
<Command>
:SWEep:XAXis:DATA?
Function
:
It queries the XAXIS data.
Description
:
Querysyntax:SWEep:XAXis:DATA?
Return
data
+1.03,+1.05,+2.05,+3.05,…+3.07(For
mat is in <NR3>)
<Command>
:SWEep:STARt <startNR3/disc>
:SWEep:STARt?
Function
:
It sets or queries the START.
Description
:
Set parameterThe start value of frequency is {10.0~30000000.0|MAXimum|MINimum}.
The start value of
voltage AC RO 100Ω is {0.01~2|MAXimum|MINimum}.
The start value of voltage AC RO 25Ω is {0.01~1|MAXimum|MINimum}.
The start value of current
AC RO 100Ω is {0.0002~0.02|MAXimum|MINimum}.
The start value of current AC RO 25Ω is {0.0002~0.04|MAXimum|MINimum}.
Setsyntax:SWEep:STARt 0.5
:SWEep:STARt 500M
:SWEep:STARt 5E-3
:SWEep:STARt MAXimum
:SWEep:STARt MINimum
Query syntax:SWEep:STARt?
Return data+5.000000E-01(Format is in <NR3>)