2

(English)

7.

Next, select the Interrupt/Request option, click
Change Setting, and use the Up/Down arrow
keys to select different IRQ number. If all IRQs
are taken, you need to contact your dealer or
computer manufacturer to help on how to free
up an IRQ in this range.

8.

When all the settings are correct, click OK

OK

OK

OK

OK to

save the modifications. The dialog box should
now show the correct Interrupt Request and
Input/Output address settings. If you’re asked
to shut down your computer, select No

No

No

No

No, then

click Close

Close

Close

Close

Close. You will be asked whether you wish

to restart your computer. Click Y

Y

Y

Y

Yes

es

es

es

es and restart

your computer.

Q3: My SCSI card is detected by Windows 98, but

the scanner cannot be found in Scanner Test
utility.

A3:

A3:

A3:

A3:

A3: Follow the steps below:

a)

In Windows, choose Start, then Shut Down to
turn off computer power. Then turn off the
power of your scanner.

b)

Check to make sure you have connected the
correct SCSI cable to the SCSI port, not the
parallel port. If you connect the SCSI cable to
the parallel port, your scanner will not be
found.

If conflicts
happen, the
message
shows here.
Currently no
conflicts
happen.

c)

If your scanner has a SCSI terminator switch,
switch it to the On position. If the scanner
doesn’t have a SCSI terminator switch, plug the
SCSI terminator on the SCSI port.

d)

If your scanner is chained to other SCSI device,
the SCSI ID of the SCSI device should not be set
to the same ID number. By default, Microtek’s
scanner SCSI ID is 6.

e)

Turn on your scanner power, then restart your
computer.

Q4: My Microtek scanner came with dual

interface -- USB and SCSI. Can I connect both
interface?

A4:

A4:

A4:

A4:

A4: When connecting dual interface scanner to

computer, you should choose either USB or
SCSI, not both.

If SCSI interface is chosen, the terminator has
to be connected to finish a complete connec-
tion. Depending on different configurations,
you may require 25-pin SCSI terminator. If USB

If USB

If USB

If USB

If USB

is chosen, the SCSI cable along with the

is chosen, the SCSI cable along with the

is chosen, the SCSI cable along with the

is chosen, the SCSI cable along with the

is chosen, the SCSI cable along with the
terminator should all be removed.

terminator should all be removed.

terminator should all be removed.

terminator should all be removed.

terminator should all be removed.

Q5: What’s the recommended power up se-

quence?

A5:

A5:

A5:

A5:

A5: When using SCSI interface, be sure you have

connected the SCSI cable and the terminator
first, then connect the DC power adapter.

Q6: I have followed the above instructions, but

still cannot fix the problem.

A6:

A6:

A6:

A6:

A6: Visit the web site of the SCSI card provider

(e.g., Adpatec or AdvanSys)

Содержание Artix Series

Страница 1: ...Settings Settings Settings and select Control Panel Control Panel Control Panel Control Panel Control Panel b From the Control Panel double click the System System System System System icon For Windo...

Страница 2: ...card IEEE 1394 was found but my scanner cannot be detected by Windows 98 SE If you are currently using the FireWire interface on Windows 98 SE you need to follow the instructions below to reinstall Fi...

Страница 3: ...ies System Properties System Properties System Properties System Properties Device Manager Device Manager Device Manager Device Manager Device Manager dialog box Step 1 and 2 then click the plus sign...

Страница 4: ...s properly connected to your computer You can only have one cable connected at a time 3 Turn the scanner on and wait until all the lights stop blinking and remain on solid If you have followed all the...

Страница 5: ...s and select Control Panel Control Panel Control Panel Control Panel Control Panel 2 Double click on the System System System System System icon in Control Panel and select Device Manager Device Manag...

Страница 6: ...n If the scanner doesn t have a SCSI terminator switch plug the SCSI terminator on the SCSI port d If your scanner is chained to other SCSI device the SCSI ID of the SCSI device should not be set to t...

Страница 7: ...ove the SCSI interface card from your computer Then re install it make sure the card is seated all the way in and secured into the PCI card slot The PCI card slot normally appears in white or ivory Q3...

Страница 8: ...SB If USB If USB If USB is chosen the SCSI cable along with the is chosen the SCSI cable along with the is chosen the SCSI cable along with the is chosen the SCSI cable along with the is chosen the SC...

Страница 9: ...your G3 remove the SCSI interface card from your Macintosh Then reinstall it make sure the card is seated all the way in and secured into the card slot Q2 My SCSI card is detected by Macintosh but the...

Страница 10: ...nnected to finish a complete connec tion Depending on different configurations you may require 25 pin SCSI terminator If USB is chosen the SCSI cable along with the terminator should all be removed Q4...

Страница 11: ...screen BIOS checking procedures To set the correct BIOS settings the following settings must be set in your computer s BIOS 1 Plug Play OS Aware YES 2 Plug Play AUTO if you have this option 3 On board...

Страница 12: ...all the scanner driver 2 Reconnect it to both the scanner and the computer 3 Turn off the scanner and turn it back on 4 Restart your computer If the USB host controller and a USB root hub appear it me...

Страница 13: ...ning operation Q2 Scanner not found A2 Make sure you have correctly connected the USB cable then restart your scanner Q3 Keyboard inactive or mouse hang up A3 Reconnect the USB cable then restart your...

Отзывы: