Microsemi PDS-104G Скачать руководство пользователя страница 44

PDS-104G PoE Switch 

Power Over Ethernet PowerView Pro User Guide 

 
 

Copyright © 2016 

Microsemi

 

 

Page 44 of 48

 

Rev. 1.0 

CPG 

– PoE BU 

 

One Enterprise Aliso Viejo, CA 92656  USA 

Recovering from Unknown Username, Password 

The procedure below describes how to recover from a scenario in which the user is unable to access the unit by 
Web or Telnet/SSH due to unknown unit username or password. 

 

 

 

NOTE: 

The recovery procedure can be performed 

only

 from the user local LAN (not over the Internet or from 

another IP Network). User should be able to turn the unit power off when needed. All PoE ports 

need

 to 

be disconnected, and the unit must have only a 

single

 active Ethernet link. 

  

 

For security concerns - username, password recovery can be performed only from Unit local LAN using unit 
IPv6 Link-Local address as FE80::9C39:DB8b:62DE:7CD4: 

 

IPv6 Link-Local is limited to local LAN since it is blocked by all routers, meaning that password recovery 
can be done only from the local LAN network, and not over the Internet or from remote IP Network. 

 

No need to configure laptop or unit IPv6 Link-Local address since it is generated automatically (MAC 
address-based). 

9.1  Summarized Username, Password Recovery Procedure (for Experts) 

1. 

Only one

 

unit Ethernet link

 may be up, leaving the other Ethernet ports disconnected. 

2. 

No PD device

 is connected, meaning no power is provided by the unit to PD device.  

3. 

Turn unit power Off

. Wait 10 seconds or so to make sure the unit is completely off. 

4.  Apply back power to the unit. And 

wait around

 

30

 seconds. 

5.  The entire procedure described below should be done in 

less than

 

120

 seconds since power was 

applied to the unit. 

6.  Connect to the unit Link-Local IPv6 address over 

Telnet over TCP port 2525

 (use the help of SysLog 

Server in order to find out unit IPv6 Link-Local address). Use 

passwordrecovery

 both as username 

and password. Trying to access the unit using any other known unit IPv4/IPv6 address will not lead to 
recovering the unit from unknown username, password. 

7.  Upon successful login, the user will be given the option to restore the unit to 

complete factory default 

including all unit Network configuration

 parameters, or cancel. Selecting the restore option will cause 

the unit to 

restore completely to factory default parameters including all unit Network configuration

 

parameters. 

8.  After unit reset, the user can regain control over unit configuration by browsing to IPv4 address 

192.168.0.50, using the default username 

admin

, and the default password 

password

 

9.2  Detailed Step-by-Step Username, Password Recovery Procedure  

1.  Please disconnect from the unit all except for one Ethernet cable (only one Ethernet port should be 

active). 

2.  Run IPv4 capable SysLog Server on your laptop/PC (make sure the firewall is turned off, or enable 

UDP port 

514

 to pass through).  

3.  Turn the unit off, wait 10 seconds, and turn it back on. A SysLog message similar to the one in 

Figure 

‎9-1: Find Unit IPv6 Link-Local address from Power-Up SysLog Report below should appear after 

15 seconds or so. Please identify unit IPv6 address (IPv6 Link-Local address always starts with FE80).  

Содержание PDS-104G

Страница 1: ...Microsemi Outdoor PDS 104G PoE Switch PowerView Pro User Guide...

Страница 2: ...CA 92656 USA Acknowledgements All other products or trademarks are property of their respective owners The product described by this manual is a licensed product of Microsemi Abbreviations and Termin...

Страница 3: ...2 3 Main Web Page Ports Status Reset 13 3 3 CONFIGURATION WEB PAGE 14 3 3 1 First Time Configuration 14 3 3 2 Security Configuration 14 3 3 3 Network Configuration 15 Configure unit IPv4 IPv6 and hos...

Страница 4: ...LOAD UNIT CONFIGURATION OVER TFTP 37 7 1 UPLOAD UNIT CONFIGURATION TO TFTP SERVER 37 7 2 DOWNLOAD UNIT CONFIGURATION FROM TFTP SERVER 38 8 SOFTWARE UPDATE 39 8 1 NETWORK MANAGER SOFTWARE UPDATE 39 8 1...

Страница 5: ...is an outdoor PoE switch that enables connecting four powered devices to the network The switch will deliver PoE power per device up to 60W for ports 1 2 and up to 30W for ports 3 4 In addition it en...

Страница 6: ...following table CONVENTION DEFINITION bold Keywords and commands italics Represents a Web interface item screen Displayed Information Courier text Information to be entered Notes Helpful information 1...

Страница 7: ...E Switch Power Over Ethernet PowerView Pro User Guide Copyright 2016 Microsemi Page 7 of 48 Rev 1 0 CPG PoE BU One Enterprise Aliso Viejo CA 92656 USA SysLog System Log SFP Fiber interface small form...

Страница 8: ...ptions o HTTP Web based friendly configuration interface for managing remote Outdoor Power over Ethernet device o HTTPS SSL TLS Secured Web based friendly configuration interface for managing remote O...

Страница 9: ...llowing PoE options are available Two 4Pair PoE Ports Delivers up to 60 watts per port Two IEEE 802 3at Delivers up to 30 watts per port PoE Enable Disable Enable disable PoE ports power output Ethern...

Страница 10: ...ice SNMP v3 Resolves SNMPv1 v2 security issues by adding authentication and encryption to layer on top of SNMP packets 2 7 Default unit IP username and password The unit is shipped with the following...

Страница 11: ...d SSL TLS Web interface handling certificates Please refer to document PDS 104G Web Certificate Management for instructions on how to create sign and upload self signed or CA signed certificates to th...

Страница 12: ...power is provided upper power indicator is on Ethernet link is on low link indicator image is green PoE port is disabled RJ45 connector marked by two red lines No Ethernet link lower link indicator im...

Страница 13: ...n Web Page Ports Status Reset Figure 3 4 Ports Status Reset Network reports for each port Ethernet link speed 10 100 1000MB and if the Network connection is up or down Status reports for each port the...

Страница 14: ...password is password Selecting the Configuration option on the menu will reveal the unit configuration Web page Please change the unit remote access username and password to other then admin password...

Страница 15: ...nable remote login via Telnet or SSH Web Encryption Force all web pages to become encrypted over SSL TLS 3 3 3 Network Configuration Configure unit IPv4 IPv6 and host name parameters Figure 3 8 Networ...

Страница 16: ...terminology as host name 3 3 4 Network Services Configuration IPv4 IPv6 Figure 3 9 Network Services Configuration DNS Server 1 DNS Server 2 Domain Name Server IPv4 IPv6 address Please note that DNS fi...

Страница 17: ...SNMPv2 SET community string For example private SNMPv2 TRAP Community SNMPv2 Trap community string For example public MIB II SysContact SNMP MIB II system contact OiD string For example John MIB II S...

Страница 18: ...no encryption similar to MD5 only using different authentication algorithm MD5 DES authentication is done by MD5 while encryption is done by DES SHA DES authentication is done by SHA while encryption...

Страница 19: ...traffic through the various ports o Reset Unit Reset the internal Network Manager internal PoE controller and internal Ethernet Switch o Reset to Factory Default Reset unit configuration to factory d...

Страница 20: ...ore PoE ports can be assigned to each PoE activation scheme NOTE For Automatic Weekly Schedule PoE Port Activation to function properly an NTP Server must be configured see Configuration Web Page prov...

Страница 21: ...y Schedule PoE Port Reset to function properly an NTP Server must be configured see Configuration Web Page providing correct GMT time Please make sure that a green OK appears to the right of the unit...

Страница 22: ...IP IP Address etc maintaining the option to access the unit over the network as before NOTE To simplify finding the unit over the network upon power up the unit will send SysLog broadcast messages to...

Страница 23: ...ble for converting URL names such as my computer com to IPv4 IPv6 addresses DNS 2 Alternate in use second DNS to be used in case the first DNS is down 3 5 1 3 Information Web Page In Use IPv6 Address...

Страница 24: ...ork Manager software version Firmware Version Unit PoE firmware version responsible for PoE functionality Boot Version NMS Boot version MAC Address Unit MAC addresses A unique 6 byte number used for E...

Страница 25: ...elnet SSH user tries to access the unit while the first Telnet SSH session is still active a short message will appear to the second Telnet SSH user requesting the user to try and reconnect over Telne...

Страница 26: ...ew Menu 4 2 1 Telnet SSH View PoE Ports Status View PoE ports status provides Network plus PoE power consumption information for each one of the ports plus overall power consumption and internal power...

Страница 27: ...rk Reports if DHCPv4 is enabled or disabled and the actual in use IPv4 address IPv4 mask and default gateway In use IPv6 Network Parameters Reports if DHCPv6 is enabled or disabled and the actual in u...

Страница 28: ...mber Unit six digit serial number Production Number Unit production number for internal use only App Ver Network Manager software version Boot Version Network Manager Boot version Firmware PoE firmwar...

Страница 29: ...owever network traffic may be interrupted for several seconds while the internal Ethernet Switch is reinitialized Upload configuration file to TFTP Server Upload unit configuration file from unit to T...

Страница 30: ...reset was done Reset unit Reset the entire unit including the internal Network Manager the PoE controller and the internal Ethernet Switch Enable Disable auto ping to Default Gateway to ensure network...

Страница 31: ...ith the SNMPv2 v3 disabled Prior to enabling SNMP please modify SNMP community strings and only then enable it 5 1 Enabling SNMP The Network Manager interface supports SNMPv1 SNMPv2c and SNMPv3 since...

Страница 32: ...Notification Privacy Password password SNMPv3 Notification Authentication and Encryption Mode None SNMPv3 Notification Table 5 1 Default SNMP usernames and passwords 2 Traps To enable traps set remote...

Страница 33: ...re 5 3 Unit supported SNMP MIB s 5 3 RFC3621 PoE MIB NOTE For a detailed PoE MIB description please refer to Microsemi s Technical Note 132 which describes in detail PoE MIB functionality RFC3621 PoE...

Страница 34: ...A Figure 5 4 MIB Tree Structure 5 4 Private MIB The following SNMP OiDs are supported by the SNMP private MIB OiD Name Type R W Description poePortConsumptionPower R PoE port power consumption Watt po...

Страница 35: ...s that may be sent by the SysLog Server Table 2 SysLog Message Types Msg ID Description Information to be provided Comments 0 System UP Will be sent each time power is provided to the unit or the inte...

Страница 36: ...y Telnet Telnet SSH with incorrect username password Remote user IPv4 IPv6 address 12 DHCPv4 Will be sent only upon the 1 st first time DHCPv4 address was obtained either by switching from static to D...

Страница 37: ...rejected please see the message below 2 For offline configuration changes please contact tech support at poesupport microsemi com 7 1 Upload Unit Configuration to TFTP Server Use the following procedu...

Страница 38: ...with the unit see Upload Unit Configuration but this time select Download configuration file from TFTP Server Figure 7 2 Download Unit Configuration 3 Type the TFTP Server IPv4 IPv6 address file name...

Страница 39: ...e Network Manager provides the graphical Web textual Telnet SSH SNMP interface between the unit and the remote Network user excluding PoE functionality which is performed by a dedicated Micro Controll...

Страница 40: ...and only then does the actual software update starts The Telnet SSH session will be lost during to the software update process However PoE power will remain during the entire software update process...

Страница 41: ...ry procedure 2 remote TFTP Server 192 168 0 50 In case unit fail to re initiate software update from remote TFTP Server as it was instructed prior power loss for example TFTP Server IP is no longer va...

Страница 42: ...enance Menu 5 Select Software update menu Figure 8 3 Selecting Software Update from the Configuration Menu 6 Select Update Unit Manager module software and type the TFTP Server IP Address see image be...

Страница 43: ...rnet PowerView Pro User Guide Copyright 2016 Microsemi Page 43 of 48 Rev 1 0 CPG PoE BU One Enterprise Aliso Viejo CA 92656 USA of the firmware update the unit will reset itself re power PD devices an...

Страница 44: ...completely off 4 Apply back power to the unit And wait around 30 seconds 5 The entire procedure described below should be done in less than 120 seconds since power was applied to the unit 6 Connect to...

Страница 45: ...Windows 7 Click Start and type cmd For Windows 8 Press the Windows key R key and type cmd 5 Type ipconfig to identify the virtual interface index of your IPv6 Link Local address 17 in the image below...

Страница 46: ...t session on TCP port 2525 Please note that the time window for password recovery is limited to 120 Sec since power up 8 Type passwordrecovery as username and passwordrecovery as password A recovery o...

Страница 47: ...he Unit Ping utility to ping the host running the TFTP Server application 2 Turn off firewall or enable UDP port 69 3 Verify that the appropriate update files package was copied to the TFTP Server roo...

Страница 48: ...itical equipment or applications Microsemi assumes no liability whatsoever and Microsemi disclaims any express or implied warranty relating to sale and or use of Microsemi products including liability...

Отзывы: