3.3.5 SNMP Configuration
SNMP configuration refers to various configuration parameters applicable both for SNMPv2c, SNMPv3 or both.
The blue title above each SNMP sub parameters group should guide the user if the parameters apply to
SNMPv2c, SNMPv3 or both.
Figure
3-10: SNMP Configuration
Enable SNMPv2
Enable/Disable SNMPv2 support.
SNMPv2 GET Community
SNMPv2 GET community string. For example
– public.
SNMPv2 SET Community
SNMPv2 SET community string. For example
– private.
SNMPv2 TRAP Community
SNMPv2 Trap community string. For example
– public.
MIB-II SysContact
SNMP MIB-II system contact OiD string. For example
– John.
MIB-II SysName
SNMP MIB-II system name. For example
– My Unit.
MIB-II SysLocation
SNMP MIB-II system location. For example
– University.
Trap Manager #1
First IPv4 / IPv6 / DNS name of remote SNMP Manager Server receiving unit trap
reports such as Cold-Start, etc.
Trap Manager #2
Second IPv4 / IPv6 / DNS name of remote SNMP Manager Server receiving unit
trap reports such as Cold-Start, etc.
Enable SNMPv3
Enable/Disable SNMPv3 support.
SNMPv3 User Name
SNMPv3 user name string.
SNMPv3 Authentication
Password
SNMPv3 password to be used by MD5 / SHA.
SNMPv3 Privacy Password
SNMPv3 password to be used by DES/AES.