PDS-104G PoE Switch
Power Over Ethernet PowerView Pro User Guide
Copyright © 2016
Microsemi
Page 38 of 48
Rev. 1.0
CPG
– PoE BU
One Enterprise Aliso Viejo, CA 92656 USA
7.2 Download Unit Configuration from TFTP Server
Download unit configuration is very similar to upload unit configuration procedure (see previous section):
1. Configure the TFTP Server as explained in Upload Unit Configuration.
2. Open a Telnet/SSH session with the unit (see Upload Unit Configuration), but this time select Download
configuration file from TFTP Server.
Figure
7-2: Download Unit Configuration
3. Type the TFTP Server IPv4/IPv6 address, file name (for example param.txt), and press
Enter
to
download the unit configuration file from the TFTP Server root folder to the unit itself.
Upon completion the unit will reset its internal Network Management module leaving PoE power
unchanged. Network traffic involving the PoE devices may be interrupted for a few seconds during the
time the Network Management Module re-initializes itself with the new configuration values.