PDS-104G PoE Switch
Power Over Ethernet PowerView Pro User Guide
Copyright © 2016
Microsemi
Page 35 of 48
Rev. 1.0
CPG
– PoE BU
One Enterprise Aliso Viejo, CA 92656 USA
6
SysLog Message Report
The unit sends various internal event reports to an external IPv4/IPv6 host running a SysLog daemon
application which logs those events for future use. For SysLog events to be sent, the user must configure
SysLog server IP address by browsing to the unit configuration Web page.
The log events are divided into three categories:
Broadcast IPv4 SysLog events to be intercepted by
any
SysLog server on the local LAN Network
regardless of unit SysLog configuration,
easing locating unit IP on the Network, and reporting major
events such as unit recovery from power failure, etc.
RFC3621 PoE traps to be sent also as SysLog messages, simplifying the readability of such events to
the remote user.
Proprietary SysLog events such as potential security breach whenever remote user tries to access the
unit over Web/Telnet/SSH with incorrect username, potential failures, etc.
6.1 SysLog Message Types
The table below summarizes the various SysLog messages that may be sent by the SysLog Server:
Table 2: SysLog Message Types
Msg
ID
Description
Information to be provided
Comments
0
System UP
– Will be sent each
time power is provided to the unit,
or the internal Network Manager
resets itself.
Reset cause
Boot status
Unit Hostname
Unit MAC Address
IPv4 Address (static/HDCPv4)
All IPv6 address
(static/DHCPv6)
Broadcast SysLog
message send to IPv4
255.255.255.255
1
PoE port status was changed
–
Will be sent whenever PoE port
state is changed, such as when PD
device is inserted / removed.
New PoE state as per one of the
defined states in RFC3621
(searching, delivering power, fault,
etc.).
RFC-3621 SNMP PoE
MIB , trap equivalent
SysLog report
2
PoE power usage exceeds xy%
percent out of Power Supply
maximum power.
Power usage percentage out of
Power Supply maximum power.
RFC-3621 SNMP PoE
MIB , trap equivalent
SysLog report
3
PoE power usage became less
than xy% percent out of Power
Supply maximum power.
Power usage percentage out of
Power Supply maximum power.
RFC-3621 SNMP PoE
MIB , trap equivalent
SysLog report
6
Default configuration
– Unit was
restored to default configuration.
SysLog Server IP is
unchanged when restoring
unit to factory default
7
Unit configuration changed
–
will
be sent whenever unit configuration
was changed.
9
PoE controller reset
–
will be sent
whenever PoE controller reset