PDS-104G PoE Switch
Power Over Ethernet PowerView Pro User Guide
Copyright © 2016
Microsemi
Page 40 of 48
Rev. 1.0
CPG
– PoE BU
One Enterprise Aliso Viejo, CA 92656 USA
Figure
8-1: Selecting Software Update from the Configuration Menu
6. Select
Update Unit Manager module software
, and type the TFTP Server IP Address (see image
below).
Figure
8-2: Selecting Update Unit Manager Module Software from the Software Update Menu
7. The files to be updated will be validated first and only then does the actual software update starts. The
Telnet/SSH session will be lost during to the software update process. However, PoE power will remain
during the entire software update process. The same is true for network connectivity between the
various switch Ethernet ports. Upon completion of the software update, the unit will send SysLog and
SNMP Trap reports.
NOTE:
Software update takes up to 10 minutes so please be patient. During this time you will be
able only to ping the unit. Upon successful software update, the unit will send SysLog IP
broadcast 255.255.255.255 to all SysLog servers located on same LAN, reporting its in use
IP, MAC Address, etc.