6-26
Quadrus Verifier User’s Manual
Dual Camera Switching
Number of External Camera Captures
Rapid Capture Mode Examples
Since examples 1 and 2 are in
Rapid Capture
mode, the cameras will continue to switch
until the
Number Of Captures
setting has been met.
Example # 1
Time Between Captures =
0,
Active camera:
Dual
Capture mode:
Rapid
, Number of captures =
7
Number of internal camera captures =
5
Number of external camera captures =
3
Note:
The third capture for the external camera does not occur because the total number of captures (7)
has been met.
Note:
In this mode, the first capture from an external camera (#6 is the above example) could be delayed
for up to 33mS until the external camera synchronizes with the reader.
Example # 2
Time Between Captures =
0,
Active Camera:
Dual
Capture Mode:
Rapid
, Number of captures =
8
Number of internal camera captures =
2
Number of external camera captures =
3
Note:
Since the total number of captures is greater than the combined number of captures of both cameras,
capture source will oscillate between the two cameras until the total number (8) has been met.
Usage:
Useful where two cameras can expect different symbols within a given read
cycle.
Definition:
The number of captures taken by the external camera before switching to
the external camera.
Serial Cmd:
<
K243,
switching mode
,
number of internal captures,
number of external
captures
,internal camera timeout,external camera timeout>
Default:
1
Options:
1 to 8
Internal
1
2
3
4
5
External
6
7
Processing
Internal
1
2
6
7
External
3
4
5
8
Processing
Up to 33mS time delay before
1st external capture.
Extra 33mS time delay
before 1st external capture.
Содержание Quadrus Verifier
Страница 1: ...Quadrus Verifier User s Manual P N 83 006702 Rev C ...
Страница 30: ...1 18 Quadrus Verifier User s Manual Generate and Save Verification Report ...
Страница 150: ...4 10 Quadrus Verifier User s Manual UII Parsing ...
Страница 152: ...Quadrus Verifier User s Manual ...
Страница 178: ...5 26 Quadrus Verifier User s Manual Aux Port System Data Status ...
Страница 210: ...6 32 Quadrus Verifier User s Manual Setting Up the Verifier for EZ Trax ...
Страница 302: ...8 62 Quadrus Verifier User s Manual Configuring EZ Trax Output ...
Страница 318: ...9 16 Quadrus Verifier User s Manual New Master Pin ...
Страница 326: ...10 8 Quadrus Verifier User s Manual Service Message ...
Страница 362: ...12 14 Quadrus Verifier User s Manual Request All Database Settings ...
Страница 390: ...14 22 Quadrus Verifier User s Manual Status Requests ...
Страница 404: ...15 14 Quadrus Verifier User s Manual Ordered Output Filter ...
Страница 444: ...A 30 Quadrus Verifier User s Manual Glossary of Terms ...