8-4
Quadrus Verifier User’s Manual
Symbol Data Output
Symbol Data Output
Note:
Symbol Data Output
relates to data and should not to be confused with
Outputs 1
,
2
, and
3
listed in the
Outputs Parameters
which describe output states and
functions.
Note: Symbol Data Output Status
if set to
Match
or
Mismatch
will not take effect unless
Matchcode Type
is enabled and a master symbol is loaded into memory.
Disabled
Match
Mismatch
Usage:
Useful when the host needs symbol data only under certain conditions.
Definition:
Defines the conditions under which decoded symbol data is transmitted to
the host.
Serial Cmd:
<
K705,symbol data output status
,when to output
>
Default:
Good Read
Options:
0 = Disabled
1 = Match
2 = Mismatch
3 = Good Read
Usage:
It is useful when an application only needs to use the discrete outputs and
can allow the reader to do the decision-making. When
Disabled
, the host
does not need the symbol data and the communication lines are used only
for setup and status checks.
Definition:
When set to
Disabled
, the reader will not transmit any data that is generated
during a read cycle (symbols, No Reads, etc.).
Usage:
Match
is used in an application that requires specific symbol information
and needs to sort, route or verify based on matching the specific symbol
data.
Definition:
When set to
Match
, the reader transmits symbol data whenever a symbol
matches a master symbol. However, if
Matchcode Type
is
Disabled
, it
transmits on any good read.
Note:
A No Read can still be transmitted if
Enabled
.
Usage:
Mismatch
is typically used as a flag within the host system to prevent an
item from being routed in the wrong container.
Definition:
With
Mismatch
enabled, the reader transmits symbol data whenever the
symbol data information does NOT match the master symbol.
Note:
A No Read can still be transmitted if enabled.
Содержание Quadrus Verifier
Страница 1: ...Quadrus Verifier User s Manual P N 83 006702 Rev C ...
Страница 30: ...1 18 Quadrus Verifier User s Manual Generate and Save Verification Report ...
Страница 150: ...4 10 Quadrus Verifier User s Manual UII Parsing ...
Страница 152: ...Quadrus Verifier User s Manual ...
Страница 178: ...5 26 Quadrus Verifier User s Manual Aux Port System Data Status ...
Страница 210: ...6 32 Quadrus Verifier User s Manual Setting Up the Verifier for EZ Trax ...
Страница 302: ...8 62 Quadrus Verifier User s Manual Configuring EZ Trax Output ...
Страница 318: ...9 16 Quadrus Verifier User s Manual New Master Pin ...
Страница 326: ...10 8 Quadrus Verifier User s Manual Service Message ...
Страница 362: ...12 14 Quadrus Verifier User s Manual Request All Database Settings ...
Страница 390: ...14 22 Quadrus Verifier User s Manual Status Requests ...
Страница 404: ...15 14 Quadrus Verifier User s Manual Ordered Output Filter ...
Страница 444: ...A 30 Quadrus Verifier User s Manual Glossary of Terms ...