Quadrus Verifier User’s Manual
7-15
Symbologies
Guard Bar (Interleaved 2 of 5)
Note:
Whenever Guard Bar is enabled, the presence of guard bars is required for decoding
to take place.
Usage:
It is useful when I 2 of 5 multisymbols are enabled to prevent false data
output. This typically occurs with highly tilted or skewed symbols.
Definition:
A guard bar is a heavy bar, at least 2 times the width of the wide bar, surrounding
the printed I 2 of 5 symbol and helping to prevent false reads.
Serial Cmd:
<
K472,
status,check digit status,check digit output status,symbol length
#1
,
symbol length #2,
guard bar
>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Содержание Quadrus Verifier
Страница 1: ...Quadrus Verifier User s Manual P N 83 006702 Rev C ...
Страница 30: ...1 18 Quadrus Verifier User s Manual Generate and Save Verification Report ...
Страница 150: ...4 10 Quadrus Verifier User s Manual UII Parsing ...
Страница 152: ...Quadrus Verifier User s Manual ...
Страница 178: ...5 26 Quadrus Verifier User s Manual Aux Port System Data Status ...
Страница 210: ...6 32 Quadrus Verifier User s Manual Setting Up the Verifier for EZ Trax ...
Страница 302: ...8 62 Quadrus Verifier User s Manual Configuring EZ Trax Output ...
Страница 318: ...9 16 Quadrus Verifier User s Manual New Master Pin ...
Страница 326: ...10 8 Quadrus Verifier User s Manual Service Message ...
Страница 362: ...12 14 Quadrus Verifier User s Manual Request All Database Settings ...
Страница 390: ...14 22 Quadrus Verifier User s Manual Status Requests ...
Страница 404: ...15 14 Quadrus Verifier User s Manual Ordered Output Filter ...
Страница 444: ...A 30 Quadrus Verifier User s Manual Glossary of Terms ...