8.3.2.2. Automatic Adjust of Sensor Current and Switching Threshold
This function serves to adjust the printer’s Sync Sensors to the material in use.
If this automatic function does not work with your specific print material, please
perform the steps described in section 8.3.2.3 Manual Adjusting of Sensor
Current and Switching Threshold.
8.3.2.2.1. Overview
yes
no
Adjust the printer to the new material to be printed
(Menu function Paper Menu\Paper type)
Material Adjust
Please adjust the
Sync Sensor(s)
of the printer
to
your print
Material
as follows:
Basic Adjust (by Factory or Service)
Shift the upper/lower sensor tot he accurate position (use the T/R marks)
Place your label (with liner) in the sensor
rea
Please follow the instructions:
Message [Load Liner]
Message [Load Black Mark] Message [Remove Paper ]
Close the printhead, during the automatic measurement [Please Wait ] is displayed
Open the printhead
Message [Load Paper ] is displayed
Open the printhead
Message [Load Label ] is displayed
Black Mark
(Reflex sensor is used)
Label (with Gap)
(Gap sensor is used)
Close the printhead
Confirm with
key
Saving the measurement as
setup value is offered
Done
Message [Adjust Error] is displayed, e.g.
Try the measurement again
(steps as described above)
Not successful ??
Adjust the sensor manually:
Proceed to the next settings: see section Adjustment of the Slip Correction) et seq.
Place your paper in the sensor
Open the printhead
Message [Load Paper ] is displayed
Select the menu function Engine\Sync.Menu\Auto.Sens.Adj.
Place your label (not the Black
Mark) in the sensor
See section
Manual Adjusting of Sensor Current and
Switching Threshold
Continuous
Autom. Measurement successful?
key enables direct branch
to page length adjustment
Switching Threshold and sensor current are displayed
Confirm with