![Micronor MR340-1 Скачать руководство пользователя страница 61](http://html1.mh-extra.com/html/micronor/mr340-1/mr340-1_instruction-manual_1788066061.webp)
MICRONOR AG
MR340-1 DIN Rail Module Controller
Page 61 of 74
6.
ZAPPY® 302 SOFTWARE
Micronor provides ZAPPY® 302 with the MR340 series Controller Module. ZAPPY® for MR302
runs on Windows XP/Vista/7/8/10 with .net Framework 4.0 installed. Zappy® 302 is used for
diagnostics and troubleshooting in case the unit appears not to work properly. Zappy® 302 is
also useful for the engineer to become familiar with the controller board.
Note: The controller utilizes RS485/RS422 type signals not directly RS-232 compatible. A
suitable signal translator is required.
If the PC has no Serial interface, a suitable USB to RS485/RS422 serial interface may be
utilized. Sections 7.1 and 7.2 illustrate two examples using USB-to-RS422/485 Converter.
6.1
How To Install and Use Zappy® 302
1.
Install ZAPPY® on your PC.
2.
Start ZAPPY® and typically it will automatically find the MR302 PCB if properly
connected to the PC via its Windows assigned virtual comm port.
3.
ZAPPY® will open up to the System Functions screen as shown in Figure 17.
When parameter(s) are changed and you want to keep them saved in the PCB, you must click
the “Set EEPROM” button.
Observe caution when changing serial interface parameters. The change will only take effect
after a power-up boot. However, it is important that you remember what parameters were set,
otherwise communication will no longer be possible with the unit.
6.2
ZAPPY® Menu Screens
System Functions screen
Figure 17 shows example of System Functions screen.
In this screen, the user can set Device Address, observe system status and error conditions.
When all parameter settings have been set (including User and Service Functions), the user
should execute SET EPROM to update Controller operating parameters stored in EEPROM.
The Error Register log can be very helpful in determining when the controller board is not
functioning properly.