MICRONOR AG
MR340-1 DIN Rail Module Controller
Page 35 of 74
Of course the encoder must be
turning otherwise the signal can be
anything from 0 to +640.
0x138
0x139
VCSEL Control
1
0 - 3
Factory use only – do NOT write to it.
Used to turn OFF the optical output
for each channel.
1 = CHA
2 = CHB
3 = Both
0x139
0x13A
Baudrate Serial
Communication
s
1
0 – 3
Sets the Baudrate for Serial
Communications on the MODBUS.
0 = 9,600
1 = 19,200
2= 38,400
3 = 57,600
4 = 115,200
0x13A
0x13B
Internal 3.3V
value
1
n/a
Gets the internal voltage in 10mV
increments.
0x13B
0x13C
Power Supply
5V
1
n/a
Gets the 5V power supply voltage in
10mV increments.
0x13C
0x13D
reserved
1
n/a
0x13D
0x13E
reserved
1
n/a
0x13E
0x13F
reserved
1
n/a
0x140
0x141
Amplifier Gain
CHA
1
0 – 255
Controls the gain of Channel A
amplifier.
0 is max gain, 255 is minimum gain
0x141
0x142
Amplifier Offset
CHA
1
0 – 255
Controls the input offset of Channel A
amplifier.
This is set at the factory only. Should
typically be a low number of less than
20.
0x142
0x143
Amplifier Gain
CHB
1
0 – 255
Controls the gain of Channel B
amplifier.
0 is max gain, 255 is minimum gain
0x143
0x144
Amplifier Offset
CHB
1
0 – 255
Controls the input offset of Channel B
amplifier.
This is set at the factory only. Should
typically be a low number of less than
20.
0x144
0x145
Optical output
Power for CHA
1
0 – 255
Controls the output power of CHA.
0 is minimum power, 255 is maximum
power.
It is used to balance each VCSEL
diode. Power output may also be
increased to compensate for long
fiber optic link losses.
0x145
0x144
Optical output
Power for CHB
1
0 – 255
Controls the output power of CHB.