8 of 17
All data can be subject to change without advanced notice. Version: December 6, 2018. © Micronel AG
5.3.2 Nominal and Threshold Values of the Blower
Electrical
Min
Nominal
Max
Voltage range
VDC
13.5
24
26.4
Constant power consumption at 43,000 rpm
W
190
General power consumption
W
220
Set speed
Voltage range
VDC
0
5
0% voltage
VDC
2
100% voltage
VDC
4.2
Stop voltage
VDC
Set speed to GND
Pneumatic overpressure
Volume flow (free-blowing)
l/min
950
Volume flow at 43,000 rpm
l/min
160
(1)
Pressure
mbar
119
Pneumatic negative pressure
Volume flow (free-blowing)
l/min
950
Volume flow at 43,000 rpm
l/min
160
(1)
Pressure
mbar
107
Thermal
Ambient temperature
°C
-20
25
45
Storage ambient temperature
°C
-20
25
65
Measuring range integrated temperature sensor
°C
-20
85
Motor
Rotational speed
RPM
22‘000
43‘000
Start-up time
(2)
s
6
Environment
Protection class housing
(3)
IP67
Relative humidity
%RH
10
85
Service life
L10
(4)
h
20‘000
L1
(4)
h
5
‘000
Acoustics
Sound pressure
(5)
dB(A)
55
61
Mechanical
Weight
kg
0.875
Dimensions
See figure 1 on page 10
Supply requirements
Ripple voltage
%
5
Continuous operation
A
10
Starting current
A
20
1 Leakage aperture
ᴓ6mm
2 Up to 90% operating speed
3 With air circulation closed to the surroundings
4 Calculated at 43,000 rpm and 25°C
5 Sound pressure level, measured at a distance of 1 m
with closed suction and pressure discharge sides
5.4.1 Materials
Components
Housing
Die-cast aluminum
Impeller
Polyamide (PA6)
Label
Polyester