micronel U100HL-024KA-4 Скачать руководство пользователя страница 6

6 of 17 

All data can be subject to change without advanced notice. Version: December 6, 2018. © Micronel AG

 

4.1 Improper Use 

 
The following are prohibited: 

Use of the U100HL-024KA-4 in non-commercial plants; 

Use in rooms or plants where explosive gases may occur; 

Suction, conveyance and compaction of explosive, inflammable, toxic or aggressive media; 

Operation of the U100HL-024KA-4 outside the permitted threshold limits specified in Chapter 5, 
“Technical Specifications”. 

 
Unauthorized modifications to the U100HL-024KA-4 are forbidden for safety reasons. 

5 Technical Specifications 

 

NOTE

 

 

 

Overheating of the U100HL-024KA-4 during operation outside the permitted range for continuous 
operation! 
Only operate the blower within the limits specified in the pQ chart and not with closed suction or 
pressure discharge nozzles. In static operation, a measuring aperture with a minimum diameter of 
6 mm or 160 l/min is to be provided. 

 

 

5.1 Performance Fields 

 
The performance fields apply to continuous operation with air as the conveyed medium at a standard 
density of 1.2 kg/m3 and an ambient temperature of 25°C. The working environment is upwardly limited by 
a characteristic curve at a constant rated speed of 43,000 rpm with tolerances according to ISO 13348 
Grade AN4.  
[Delta pressure and /- 10%, power consu 16%, aco 6dB (A)] 
 
 

 

 

 

 

Содержание U100HL-024KA-4

Страница 1: ...a can be subject to change without advanced notice Version December 6 2018 Micronel AG Original Operating Manual German OPERATING MANUAL U100HL 024KA 4 Micronel AG Z rcherstrasse 51 CH 8317 Tagelswang...

Страница 2: ...formance Fields 6 5 2 Mechanical Nominal and Threshold Values of the Blower 7 5 3 1 Dimensions 7 5 3 2 Nominal and Threshold Values of the Blower 8 5 4 1 Materials 8 5 5 1 Mounting 9 5 5 2 Sound and V...

Страница 3: ...k is the observance of all safety instructions in this manual Illustrations in this manual are provided for basic understanding and may differ from the actual design Please check to see if the manual...

Страница 4: ...e to people Danger from ejected parts Do not insert any objects through the opening in the U100HL 024KA 4 Danger from rotating and pressurized parts Before starting work on the U100HL 024KA 4 Disconne...

Страница 5: ...rate the U100HL 024KA 4 only with gases as described in Chapter 4 Intended Use with the values as specified in Chapter 5 Technical Specifications Transport assembly and disassembly may only be carried...

Страница 6: ...ecifications NOTE Overheating of the U100HL 024KA 4 during operation outside the permitted range for continuous operation Only operate the blower within the limits specified in the pQ chart and not wi...

Страница 7: ...change without advanced notice Version December 6 2018 Micronel AG 5 2 Mechanical Nominal and Threshold Values of the Blower 5 3 1 Dimensions Figure 1 Dimensions of the U100HL 024KA 4 in mm Pipe thre...

Страница 8: ...7 Thermal Ambient temperature C 20 25 45 Storage ambient temperature C 20 25 65 Measuring range integrated temperature sensor C 20 85 Motor Rotational speed RPM 22 000 43 000 Start up time 2 s 6 Envir...

Страница 9: ...re tension Do not exceed the maximum tightening torque of 8 Nm This is to avoid damaging the housing Maintain a minimum distance of 60 mm on each side for heat dissipation NOTE Risk of overheating thr...

Страница 10: ...ace maximum 75 C of the U100HL 024KA 4 High surface temperatures of over 75 C may occur on the surface of the U100HL 024KA 4 during operation No temperature sensitive parts such as electrical lines or...

Страница 11: ...e Plug type Binder miniature circular connector plug series 423 M16 DIN 8 pin male Plug recommendations Self assembled Female M16 Binder circular connector plug series 423 DIN 8 pin Pre assembled 2 m...

Страница 12: ...erator rpm speed min 1 6 1 3 3 NTC Temperature Monitoring NTC NTCG164KF104F TDK 6 2 Pipe and Hose Connections The conveying direction is labeled with IN at the intake and OUT at the outlet The gases v...

Страница 13: ...ection of at least 12 cm in length must also be connected during operation with opened suction nozzles suction from or discharge into the surrounding area to prevent fingers from coming into contact w...

Страница 14: ...e of 4 mm and 80 l min is specified for static operation Risk of overheating through the prevention of natural convection The U100HL 024KA 4 is passively cooled Observe the permissible housing tempera...

Страница 15: ...A 4 Disconnect from the power supply Secure against restarting Determine the absence of voltage Vent pipes and pump depressurization Before re commissioning Check that all fastening elements have been...

Страница 16: ...w Check voltages Fan or system is leaking Check torques and seals on the connection lines Flow rate is too low Line is clogged impeller is dirty Clean line impeller Speed is too low Check voltages Pre...

Страница 17: ...s Measures after de commissioning or before storage Attach caps to the suction and pressure discharge nozzles Ensure proper storage conditions see below Storage conditions Ambient temperature 20 C to...

Отзывы: