12 of 17
All data can be subject to change without advanced notice. Version: December 6, 2018. © Micronel AG
oder
SP not connected
Blower runs at 100% speed
SP connected to GND
Zero speed
stop
6.1.3.2 FG speed/Frequency Signal
Speed calculation
f*20 = rpm (3 pulses / revolution)
f = FG Frequency generator
rpm = speed [min
-1
]
6.1.3.3 NTC Temperature Monitoring
NTC
NTCG164KF104F (TDK)
6.2. Pipe and Hose Connections
The conveying
direction is labeled with “IN” at the intake and “OUT” at the outlet.
The gases/vapors to be conveyed are sucked in through the suction nozzle and discharged via the
pressure discharge nozzle.
The
suction nozzle
is labeled with “IN”. Connect the suction line here.
The
pressure discharge nozzle
is labeled with “OUT”. Connect the pressure line here.
5V
0V
Tachometer
Voltage