© Microhard Systems Inc.
55
4.0 Configuration
Image 4-2-11: Network Configuration , Local Monitor
4.2.8 Network > Local Monitor
The Local Device Monitor allows the IPn4G to monitor a local device connected locally to the
Ethernet port or to the locally attached network. If the IPn4G cannot detect the specified IP or a
DHCP assigned IP, the unit will restart the DHCP service, and eventually restart the modem to
attempt to recover the connection.
IP Mode
Select the IP mode. By selecting a fixed IP address the service will monitor
the connection to that specific IP. If auto detect is selected, the IPn4G will
detect and monitor DHCP assigned IP address.
Status
Enable or disable the local device monitoring service.
Disable /
Enable
Values (selection)
Fixed local IP
Auto Detected IP
Values (selection)
Local IP Setting
This field is only shown if Fixed Local IP is selected for the IP Mode. Enter
the static IP to be monitored in this field.
0.0.0.0
Values (IP)
Status Timeout
The status timeout is the maximum time the IPn4G will wait to detect the
monitored device. At this time the IPn4G will restart the DHCP service. (5-
65535 seconds)
10
Values (seconds)
Waiting DHCP Timeout
This field defines the amount of time the IPn4G will wait to detect the
monitored device before it will reboot the modem. (30-65535 seconds)
60
Values (seconds)
Содержание IPN4G