© Microhard Systems Inc.
172
5.0 AT Command Line Interface
AT+MIS
Command Syntax
Module Input Status.
AT+MIS
Description
Example
Input:
AT+MIS <enter>
Response:
+MIS: available input status
INPUT 1: 0 open
OK
AT+MOS
Command Syntax
Module Output Status.
AT+MOS=<Mode>[,<Setting No.>,<Status>]
Mode:
0 All Output Status
1 Output Setting
Setting No.: 1, 2, 3, 4(if output available)
Status:
0 open
1 close
Description
Example
Input:
AT+MOS=0 <enter>
Response:
+MOS: available output status
OUTPUT 1: 0 open
OK
Input:
AT+MOS=1,1,1 <enter>
Response:
OK
AT+IMEI
Command Syntax
Check Modem’s IMEI Number.
AT+IMEI
Description
Example
Input:
AT+IMEI <enter>
Response:
+IMEI: 012773002108403
OK