![MICRO-EPSILON scanCONTROL 29 50 Series Скачать руководство пользователя страница 57](http://html1.mh-extra.com/html/micro-epsilon/scancontrol-29-50-series/scancontrol-29-50-series_operating-instructions-manual_1785369057.webp)
Page 57
scanCONTROL Output Unit
scanCONTROL 29xx
7.4.4
OU-AnalogOut/4-Channel/0-10 V
- Micro-Epsilon art. no. 0325135
- 4-Channel analog output terminal DC 0-10 V
- Indicators (Status-LED’s, for detailed description refer to manual of
the 4-Channel analog output module DC 0-10 V)
- Voltage range is terminal-related 0 to +10 V and can not be
extended by changing the appropriate setting in scanCONTROL
Configuration Tools.
- The output signal is galvanically isolated output from the system
level.
- The resolution is limited to 12 bits.
- scanCONTROL 2910/2960 supports four analog outputs.
Fig. 34 4-Channel-AnalogOut-Modul
Number of outputs
4
Power supply
via system voltage DC/DC
Signal voltage
0 V ... 10 V
Load
> 5 kΩ
Resolution
12 bit
Conversion time
typ. 10 ms
Settling time
typ. 100 µs
Measurement error at 25 °C
<± 0.1 % of full scale (FS)
Temperature coefficient
<± 0.01 % /K of full scale (FS)
Fig. 35 Technical data of analog output module