![MICRO-EPSILON scanCONTROL 29 50 Series Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/micro-epsilon/scancontrol-29-50-series/scancontrol-29-50-series_operating-instructions-manual_1785369032.webp)
Page 32
Mounting and Installation
scanCONTROL 29xx
The multifunction socket can be used with either of the following configurations:
Configuration
Direction
Standard setting for terminating resistor R
T
0
Half-duplex, serial communi-
cation with 115200 Baud
input/output
On
1
Half-duplex, serial communi-
cation with 57600 Baud
input/output
2
Half-duplex, serial communi-
cation with 38400 Baud
input/output
3
Half-duplex, serial communi-
cation with 19200 Baud
input/output
4
Half-duplex, serial communi-
cation with 9600 Baud
input/output
5
External trigger input
input
On
6
External trigger output
output
Off
7
CMM trigger output
output
Off
Synchronizing several sensors with each other:
Connect the output RS422+ (Pin 12) of sensor 1 with the input RS422+ (Pin 12) of sensor 2.
Connect the output RS422- (Pin 11) of sensor 1 with the input RS422- (Pin 11) of sensor 2.
Also connect both the GND-In1 - pins (Pin 4) of the sensors to each other.
Software settings:
Setting
Sensor 1
Sensor 2
Sensor 3
RS422 mode
External trigger output
External trigger input
External trigger input
No RS422 termination
No (terminating resistor
not active)
Yes (terminating resistor
not active)
No (terminating resistor
active)
Fig. 19 External synchronization settings
The sensor 1 then synchronizes the sensor 2 and further sensors as master.