![MICRO-EPSILON scanCONTROL 29 50 Series Скачать руководство пользователя страница 43](http://html1.mh-extra.com/html/micro-epsilon/scancontrol-29-50-series/scancontrol-29-50-series_operating-instructions-manual_1785369043.webp)
Page 43
Operation of the Sensor with a PC
scanCONTROL 29xx
The measuring field can be restricted by omitting complete matrix areas in order to suppress interfering im-
age ranges.
The following measuring fields are used in the demonstration program, see Chap.
.
Name
Index
Large
0
Standard
2
Small
7
Fig. 24 Measuring fields used
Measuring field and measuring range must be clearly differentiated in practical use. The measuring field is
related to the matrix and the measuring range is related to the measuring object (the object space).
Both do not have to match on account of the optical mapping and the definitions.
i
The „Standard“ measuring range and the „Standard“ measuring field are not congruent. The minimum
dimensions can be found in the dimensional drawings
Characteristics of the sensors:
- a laser line with 20° aperture angle (measuring range 25 mm) or 25° ope aperture angle (measuring
ranges 50 mm and 100 mm).
- The receiver has a smaller aperture angle (view angle) than the laser line.
- Centered measuring field (symmetrical to the center axis).
- The high resolution sensor image matrix evaluates 1280 x 1024 pixels. The measuring field geometry is
fixed.
- Reference for the distance (Z-axis) is the lowest body edge of the sensor
- Use of the GigE-Vision standard. The description is included in the documentation of the scanCONTROL-
Configuration Tools.