Page 67
Serial Interface RS422
optoNCDT 1402
Reply:
31
24 23
16 15
8 7
0
hex
„l“
„L“
„D“
„1“
0x494C4431
0xA0
0xFA
0x00
0x02
0xA0FA0002
0x20
0x20
0x0D
0x0A
0x20200D0A
Data Protocol ILD1401
8.3.25
Name:
SET_CIMODE_1401
Description:
Switches the sensor into the ILD1401 data protocol.
The sensor replies with the ILD1402 data protocol, after sending the reply the sensor switches the data proto-
col.
The following parameters can be changed in the ILD1401 data protocol:
Digital or analog data output
-
Behavior in case of an error
-
Averaging
-
The other parameters remain fixed:
Baud rate: 38400
-
Measurement rate: 1000 Hz
-
Type of digital output: binary
-
Mode of analog/digital output: continuous
-
Key status: auto lock
-
Mode of save setting: save at each time
-
Mode of external input: as teach in
-
Teach value 1: 0.00 resp. taught value T1 remains
-
Teach value 2: 16368.00 resp. taught value T2 remains
-
Format: 31
24 23
16 15
8 7
0
hex
„+“
„+“
„+“
0x0d („CR“)
0x2B2B2B0D
„l“
„L“
„D“
„1“
0x494C4431
0x20
0xF2
0x00
0x02
0x20F20002