Page 61
Serial Interface RS422
optoNCDT 1402
Name:
LASER_ON
Description:
Switches on the laser
Format: 31
24 23
16 15
8 7
0
hex
„+“
„+“
„+“
0x0d („CR“)
0x2B2B2B0D
„l“
„L“
„D“
„1“
0x494C4431
0x20
0x87
0x00
0x02
0x20870002
Reply:
31
24 23
16 15
8 7
0
hex
„l“
„L“
„D“
„1“
0x494C4431
0xA0
0x87
0x00
0x02
0xA0870002
0x20
0x20
0x0D
0x0A
0x20200D0A
i
The command LASER_ON is effective only if pin 8 is connected with GND.
Change Data Format
8.3.18
Name:
ASCII_OUTPUT
Description:
Switches the data format for the measurement value output via the digital interface. The com-
mand replies will remain unaffected.
Parameter:
X = 0 --> Binary output (2 Byte)
-
X = 1 --> ASCII output (6 Byte)
-
Format: 31
24 23
16 15
8 7
0
hex
„+“
„+“
„+“
0x0d („CR“)
0x2B2B2B0D
„l“
„L“
„D“
„1“
0x494C4431
0x20
0x88
0x00
0x03
0x20880003
0x00
0x00
0x00
0x0X
0x0000000X
Default setting:
Binary format