Page 102
Warranty
optoNCDT 1320
Selection of peak
First peak /
Highest peak /
Last peak
Defines which signal is used
for the evaluation in the line
signal.
First peak: Nearest peak to
sensor.
Highest peak: standard, peak
with the highest intensity.
Last peak: widest peak to
sensor.
0
50
0
100
50
Range [%] 100
First
peak
Last
peak
Highest
peak
faraway
close
Sensor
Intensity
[%]
Error handling
Error output, no measurement value
The analog output supplies 3 mA instead of measurement value. The
RS422 interface outputs an error value.
Hold last value infinite
Analog output and RS422 interface stop at the last valid value.
Hold last value
1 ... 1024
Value
Zeroing/
Mastering
Inactive
Normal measurement value resp. Zeroing/Mastering is undone.
Active
Value
Indication e.g. of thickness of a master part.
Value range 0 up to max. + 2 x measuring range