Page 47
Set Sensor Parameter
optoNCDT 1220
7.5
Outputs
7.5.1
Overview
RS422
Baud rate
9.6 / 19.2 / 56.0 / 115.2 /
230.4 ... / 1000 kBps
Transmission rate with binary data format.
Output data
Distance / Measurement
counter
The data which are provided for the transmission are to activate with the
checkbox.
Analog
output
Standard scale
Start of measuring range 4 mA, end of measuring range 20 mA
Two-point scale
Minimum value
Value
Always 2 points which mark the start and end of a new measuring range
are taught. Reversal of the output signal is possible with two-point scaling.
Maximum value Value
Switching
output
Inactive
Measuring range
NPN / PNP / PushPull /
PushPullNeg
The switching output is switched when the received signal is not (entirely)
in evaluation range (ROI).
Analog range
NPN / PNP / PushPull /
PushPullNeg
The switching output switches when the scaled analog range is exceeded.
Limit monitoring
NPN / PNP / PushPull /
PushPullNeg
The error output switches when the limit value is exceeded.
Limit
mm/inch
Value
Hysteresis
mm/inch
Value
Value by which the measured value must fall short of the limit value to
deactivate the switching output.
Minimum
holding period
Value
Indicates in 1 ... 1000 ms how long the switching output must be active at
least when the limit value is exceeded. This time period starts when the
limit value is exceeded.
Output
interface
Analog / RS422
Selects the used interface. If the RS422 interface is used, signal graphs
cannot be shown by the web interface. If the analog output is used, signal
graphs can be shown by the web interface, too.