Page 70
Appendix | Factory Settings
optoNCDT 1220
A 2
Factory Settings
Password
„000“
Language
German
Measuring rate
1 kHz
Output
Analog current
Measuring range
100 % FSO: I = 20 mA
RS422
921.6 kBaud
0 % FSO: I = 4 mA
Trigger mode
No trigger
Error handling
Error output, no measurement
Fig. 42 Factory settings standard sensors
Balanced
Moving average with 64 values
Language
Chinese
Measuring rate
1 kHz
RS422
115.2 kBaud
Fig. 43 Factory settings series ILD1220-x(214) sensors
LED
State
normal operation
Key
Select
Supply
voltage
red
flashes yellow approx. 8 Hz
flashes yellow approx. 1 Hz
yellow green
t
0
10 ... <15 s
t
1
t
3
t
2
10 s
t
4
Fig. 44 Flow chart to start a sensor with factory setting
t
0
:
power supply is on
t
1
...
t
3
: both LEDs signalize the start sequence (red-yellow-green for 1 sec. each)
t
2
:
key is pressed during start sequence (
t
1
...
t
3
)
t
4
:
key is released while the LED
State
is flashing yellow
D
t
=
t
4
-
t
2
;
D
t
(key press period) must be at least 10 sec., max. 15 sec.