background image

Micro-Air provides a 9-pin harness that will be used to interface between EasyTouch and the RV 

manufacturer’s wires. One side plugs into EasyTouch

 RV while the other wire end side is used to make 

your  new  wire  connections.  You  will  have  to  source  or  reuse  electrical  connectors  to  make  these 
connections. 

EasyTouch will also have a pre-wired 2-pin connector and a pre-wired 3-pin or 4-pin connector 

attached to the back. You will have to cut off these plugs and use electrical connectors to complete the 
installation per 

Table 4

. Any unused wires or plugs you can cut short or leave untouched. 

When you know where each wire goes you should begin cutting wires. Move through them one 

at a time, replacing an OEM thermostat wire with the appropriate EasyTouch wire until all the wires are 
replaced. 

 

Direct Wired 

 Webasto (TrueAir) Special Considerations 

 

Some Webasto (TrueAir) thermostats may have an additional consideration. Some of them had a 

freeze sensor while some used an AGS (Auto-Generator Start) output, but never both. Inspect your OEM 
thermostat wires for either two gray wires or a green wire. As per 

Table 4

connect your gray wires to the 

gray wires of the Micro-Air 9-pin harness (polarity does not matter) or connect your green wire to the pin-
3 gray wire of the Micro-Air 9-pin harness. Pin-3 is the gray wire next to orange and red. See the 

Auto-Gen 

Start 

section in 

Initial Setup Instructions 

to tell the thermostat how you have it wired. 

 

Re-apply Power 

 

Restore DC power and the thermostat screen should light up and boot into the main menus. This 

will happen if the four power wires are connected properly. All other wires control the outputs or are 
sensors. Restore AC power so that your appliances can run again. Move on to the section 

Mounting the 

Thermostat

or the sectio

Initial Setup Instructions

 and mount the thermostat later. 

 

Содержание ASY-356-X01

Страница 1: ...EasyTouch RV 356 Operating Manual Revision 1 0...

Страница 2: ...o Gas Changeover 13 Local Weather and Local Time 14 Status Messages 14 Settings Screens 15 Schedule Screens 18 Create and Enable a Schedule 19 Smart Device Application Features 20 Restart Thermostat 2...

Страница 3: ...k Single Dual Stage Compressor ASY 356 X02 ASY 356 X04 White Table 1 Table 2 and Table 3 list the known OEM model numbers that can be used with EasyTouch RV 356 The tables are not exhaustive so if you...

Страница 4: ...s then you can simply plug in all the mating connectors and move on to the section Mounting the Thermostat The provided wire 9 pin wire harness will not be needed Not all installations will use all pl...

Страница 5: ...y Freeze Sensor 1 Red 2 Red 12 VDC Out Gray 3 Gray Freeze Sensor Green 3 Gray AGS Blue 4 Blue 12 VDC Ground Out Yellow 5 Yellow Compressor 1 Orange 6 Orange Compressor 2 Black 7 Black Indoor Fan High...

Страница 6: ...eAir Special Considerations Some Webasto TrueAir thermostats may have an additional consideration Some of them had a freeze sensor while some used an AGS Auto Generator Start output but never both Ins...

Страница 7: ...w and level the buttons so the display will be straight when installed Step 3 Screw in second screw making sure the two buttons remain level Step 4 Remove mounting tab before mounting on the wall Step...

Страница 8: ...f the thermostat but it must be configured to know if it is available Tap the AGS Available Unavailable button under the Auto Gen Start heading to set it based on what you have If set as Available the...

Страница 9: ...connection No icon means no connection to an internet enabling device Red means it is connected to an internet enabling device but does not have internet Green means it is connected to the internet Th...

Страница 10: ...ways on regardless of heating or cooling with number of bars indicating speed Fan Auto turns the fan on and off with a cooling or heat pump cycle and operates as Fan Off in all other operational modes...

Страница 11: ...ttings See section Temperature Gap Hysteresis for details Heat Pump Only Mode This mode only runs an electric overhead heat pump heating cycle to maintain the heating set point in the space Set the 7...

Страница 12: ...points that are separate heating and cooling set points No heating or cooling cycles will occur when the inside temperature is between the set points This can be useful when setting a higher day time...

Страница 13: ...ge 2 Run Until Setpoint is Satisfied Inside 7 Or More Below Setpoint Stage 1 Stage 2 and Stage 3 Run Until Setpoint is Satisfied or Any Stage Runs 20 Minutes Stage Escalates to the Next Highest Availa...

Страница 14: ...location If power is interrupted or the device is restarted it will go out to the internet to grab the current time when the internet connection is re established without app interaction Status Messa...

Страница 15: ...y off after 30 seconds of no screen presses The display will brighten again after a screen press to the Active Level set in the Display Brightness settings Display Brightness This screen allows you to...

Страница 16: ...operational example Inside Temperature F Heating Setpoint F Heating Gap Setting F System Operation 69 68 3 None 66 None 65 Heating Cycle Begins 67 Heating Cycle Continues 69 Heating Cycle Terminates...

Страница 17: ...e appropriate This setting allows for a generator to start prior to any appliances that need line voltage to run EasyTouch RV will output voltage to its pin 3 grey wire to go to existing AGS hardware...

Страница 18: ...of the week is selected from the days along the top of the screen The day selected appears in white 2 Scheduled Events Events are numbered 1 to 6 along the left side of the display Tap an event to edi...

Страница 19: ...is enabled for EasyTouch RV models that are not zone controls will not have this feature and will always be enabled when a valid Action Time 1 is used Create and Enable a Schedule Tap the edit schedu...

Страница 20: ...ostat in the app selecting the settings gear and then selecting notifications A minimum and maximum allowed temperature can be set Table 13 shows an example of operation with an 80 F maximum temperatu...

Страница 21: ...Bluetooth is enabled and that the app has Bluetooth and location services permissions 2 Start the app on your smart device The app will open and if you have not entered your account information it wi...

Страница 22: ...ly enter the SSID manually case sensitive b Enter the password case sensitive 4 Press OK and the screen will return to the selection screen The thermostat will reset and a green Wi Fi symbol will appe...

Страница 23: ...oting of the component fan compressor furnace heat pump heat strip is required If 12 volts is not present verify that the fuse in EasyTouch RV is still good Wi Fi Troubleshooting No Wi Fi Icon SSID Ne...

Отзывы: