Veri-Q PREP M16 G2-16TU  

User Manual

2. Safety Guideline

This manual contains information and warnings the user must follow for the safe use of Veri-Q 
PREP M16-G2-16TU. Hazards that could harm the user or damage theequipment are clearly stated 
in this manual. If the product is used in a manner notdesignated by the manufacturer, the product 
may become damaged.

Safety regulations are used like the following.

Warning

Warning is used to inform the user or other users that a situation like injury can 
occur. Details about these situations are included in a box like this.

Caution

Caution is used to inform the situation that can cause damage to the product or 
other equipment. Details about these situations are included in a box like this.

Before using the equipment, please read this manual carefully. And pay attention to the advice on 
all hazards that may arise during operation. The caution clearly stated in this manual is intended to 
supplement, not replace, safety requirements applied to the user’s country.

2.1  Precautions when using the device

2.1.1

  Veri-Q PREP M16–G2-16TU must be only used by skilled personnel who have received 

training on the relevant area.

2.1.2

  Please thoroughly familiarize yourself with the manual before using the product We 

recommend the user to read the warnings represented by symbols.

 

Warning

Risk of Injury and Damage to Materials

Improper use of G2-16TU may cause injury to the user or damage the product. G2-
16TU must only be used by users qualified after completing a training course.
Servicing on G2-16TU is performed by MiCo BioMed.

2.1.3

  The user must use only components of MiCo BioMed in order to receive guarantee of the 

product. Please perform regular maintenance according to the user manual. MiCo BioMed charges 
the repair cost regarding problems arising due to incorrect maintenance.

2.1.4

  In case of an emergency or malfunction, turn off the power switch on the back of G2-16TU, 

and unplug the power cord from the power outlet.  Afterwards, contact the contact address 
specified on the user manual.

1. Before You Begin

1.1  About the manual

This manual is prepared for researchers or related staff for using and conducting research using 
Veri-Q PREP M16-G2-16TU and for related staff who installs and maintains the product. This 
product is a medical device. 

1.2 General Requirements for Installation

If you wish to use this manual, the following is required. 
-You must have basic knowledge in handling DNA and RNA samples for PCR.

1.3 How to Obtain More Information 

To obtain detailed information on Veri-Q PREP M16-G2-16TU, please visit the following website 
http://micobiomed.com/ or contact us at the following address. [email protected] 

1.4 About Customer Support

For prompt response to customers, please contact us at +82-70-5227-6000.
Technical support is also available at our website at http://micobiomed.com.

1.5 Precautions on distribution or duplication of the manual

The content of this document cannot be sent or duplicated without the permission of the 
copyright holder : MiCo BioMed Co., Ltd. 

 

1.6 Laboratory Biosafety

Non-propagative diagnostic laboratory work (e.g. sequencing, NAAT) should be conducted at 
facilities and procedures equivalent to BSL-2.

Содержание 9S101

Страница 1: ...Veri Q PREP M16 G2 16TU User Manual Apr 2020 Cat No 9S101...

Страница 2: ...16TU For safe use please use the device after reading the manual thoroughly Please furnish this document at a designated location so it can be used at all times MiCo BioMed Co Ltd 3rd and 4th Floor 54...

Страница 3: ...3 How to Obtain More Information 6 1 4 About Customer Support 6 1 5 Precautions on distribution or duplication of the manual 6 1 6 Laboratory Biosafety 6 2 Safety Guideline 7 2 1 Precautions when usi...

Страница 4: ...pleting a training course Servicing on G2 16TU is performed by MiCo BioMed 2 1 3 The user must use only components of MiCo BioMed in order to receive guarantee of the product Please perform regular ma...

Страница 5: ...ppropriate data values 2 1 5 If the device does not meet the performance conditions make an inquiry to the manufacturer 2 1 6 This device is an electronic and mechanical device Since there is a risk o...

Страница 6: ...or fumes and disposal of wastes must follow all national and local health and safety regulations and laws Please wash your hands after handling the reagents 2 2 19 Operate the product in an environmen...

Страница 7: ...each parts Near sample tubes Biological hazard Since the tubes or waste cartridges become contaminated with biohazardous materials they must be handled while wearing gloves Near buffer bottles and sam...

Страница 8: ...tantaneous maximum power consumption 110W Safety device We made sure the electric shock inside the board does notaffect the element by using Varistor on operating parts such as valve pump fan etc We m...

Страница 9: ...l be filled in this waste cartridge Lid This lid will cover the Elution Cartridge 3 6 Equipment Part Names and Functions 1 2 3 4 5 6 7 No Name Explanation 1 LCD Operates and sets equipment with touch...

Страница 10: ...y Fluid control part for washing air pumping and extraction Moving part to perform pre treatment per channel 4 1 2 Operation Principle This device has the function to rapidly extract nucleic acid from...

Страница 11: ...e G2 16TU and then turn on the power 2 When power is supplied to the device POWER LED should light up Please refer to the following photo The green light coming on means the device is working properly...

Страница 12: ...place a Pre run Cartridge in an appropriate position of Sample Rotor Do not place the Pre run cartridge upside down The buffer solution can flow into the equipment Please refer to the photo below X O...

Страница 13: ...nge menu page by pressing image or pressing button You can check the firmware version on the left corner The latest version is v2 00 4 5 8 Select extraction volume 1 Press E Volume image or button You...

Страница 14: ...ration 4 5 9 Start operation 1 Press START button or Start image The equipment automatically operates Please refer to the following for operating procedures A Checking Binding When the user operates t...

Страница 15: ...e visit http micobiomed com or send an e mail to salesbio micobiomed com C Elution In this step the eluate will be gathered in the micro tube which is inserted into the elution cartridge Because G2 16...

Страница 16: ...ipment b When sample extraction is complete In this case take the following measures a Remove all sample tubes from the upper tray b Press INIT image or SET button Washing1 Buffer Empty This error mes...

Страница 17: ...ed purchase information please check the homepage http micobiomed com 7 Warranty Policy MiCoBioMed shall be excluded from warranty obligations when a person other than the dedicated engineer performs...

Страница 18: ...of the upper tray And if necessary wipe the hole of the upper tray with a cotton swab 12 2 4 Open even the lower tray and wipe it in the same manner 12 3 Cleaning of Pre run Cartridge 12 3 1 Dispose...

Страница 19: ...ound the equipment The device is not exposed to direct sunlight There are no installations that can cause dust heat and fluid inflow into the equipment The port switch direction on the rear of the equ...

Страница 20: ...not be required to replace any unit which is damaged or malfunctions due to abuse accidents alteration neglect misuse maintenance by someone other than Mico BioMed co Ltd or failure to operate in acco...

Страница 21: ...Veri Q PREP M16 G2 16TU MiCo BioMed Co Ltd 3rd and 4th Floor 54 Changeop ro Sujeong gu Seongnam si Gyeonggi do Korea 13449 TEL 82 70 5227 6000 FAX 82 70 5227 6001 2 User Manual Apr 2020...

Отзывы: