Preparing the collectors
1. Position the square nuts in the slot on the back of the collector with a
screwdriver and secure them with the installation aid (5.4).
Using the installation aid, the square nut can easily be positioned for further
installation of the T-pieces when the collector (1) has been erected.
2. Preassemble four T-pieces (5.1/6.1) for each collector with M8 hexagonal bolts
(5.2/6.2) on the square nuts in the slot on the rear of the collector. To do so, align
the first square nut with the help of the long side of the installation aid. Attach
the T-piece and screw in a hexagonal bolt.
Align the second square nut by turning the installation aid and screw in another
hexagonal bolt.