MHG Heating Ltd ©
MHG Heating Ltd. Unit 4 Epsom Downs Metro Centre, Waterfield Tadworth Surrey KT20 5LR
P: 08456 448802 F: 08456 448803 E:[email protected] W:
www.mhgheating.co.uk
01/01/10
35
Install the C-profile with T-headed screws on the roof hooks. 6
Attention: in the range of the roof hooks, the quickies for the fastening of the
collectors cannot snap in the bar. Therefore, do not install the roof hooks right in
the centre between two collectors.
Insert the T-headed screw into the C-profile and screw it in as far as it will go. By
means of the notch at the end of the thread, the correct position of the screw can
be verified
The bars are aligned parallel if measure C = D (e.g. measured with a string). When
aligned correctly, the bars can be screwed tightly.