32
24.11.14 / V 01.0-EN
Servicing
Servicing 6
Use the screwdriver for levering up the spiral spring
so that you can replace the consumed coal.
Hold the spiral spring
and put in the
new coal into the guide.
Make sure that the connecting lead is fixed and
Is screwed together with the coal connecting lead.
Close the brush holder cap and replace the brush
on the other side by the same method.
Also close the brush holder cap, push firmly together
the case and the handle and screw it again.
The machine is now ready for use.
After a replacement of the carbon brush the brush-fire is initially slightly
larger, but after short time will be the normal small brush-fire of bluish
8
9
10
11
8
9