1. Delivery condition 

The 

E-NERGY CARBON

 panel heating system can be used as a full heating system, auxiliary heating or for  

surface tempering can be used in the renovation (e.g. mould prevention).

1.1 Scope of delivery

• E-NERGY CARBON power supply unit BASIC TT  
• Installation instructions & operating manual

The following additional products are required for the complete E-NERGY CARBON system:
• Assembled heating foils from 60 to 290 W/m² 
• E-NERGY CARBON room thermostat 

2. Information for users

 

Please read these operating instructions carefully before installation and follow the instructions. The 

E-NERGY 

CARBON

 system can be used by children aged 8 years and older and by persons with reduced physical, sensory or 

mental abilities or lack of experience and knowledge, if have been supervised or instructed in the safe use of the 
device and the resulting understand the resulting dangers. Children must not play with the device. Cleaning and 
user maintenance must not be carried out by children without supervision.  
A copy of the operating instructions must be kept in the circuit distribution box. In case of change of ownership the  
Please inform the subsequent owner about the installation. In humid/wet rooms DIN VDE 0100 part 701  
be taken into account. If the 

E-NERGY CARBON

 heating foil is installed under e.g. a tiled floor (preferably 

underneath the sealing) in a humid/wet area (e.g. shower), this area does not count as protection area 0, 1 or 2 
according to DIN VDE 0100 part 701. Installation is permitted under these conditions.  

2.1 Safety instructions

•  Please read this manual carefully and completely before you start the installation.

•  Transport: To protect all parts from damage, they should remain in their original packaging until they reach the  
 

installation site. Internal parts can be damaged by shock and fall.

•  Damaged equipment or parts must not be put into operation.

•  Do not remove the safety labels and type plates.

•  The individual components may only be installed in closed rooms.

•  All assembly and installation work must always be carried out in a de-energised state.

•  he circuit for connecting the power supply unit must be sufficiently dimensioned and fused for installation.  
 

When operating the heating system, this circuit must not be overloaded. 

•  The device is not ready for operation when delivered and must first be connected by a qualified electrician. 

Содержание E-NERGY CARBON BASIC TT 1200

Страница 1: ...E NERGY CARBON Electric surface heating system Installation instructions operating manual Power supply unit BASIC TT mfh systems modern floor heating mfh systems modern floor heating...

Страница 2: ...02 INSTALLATION SKETCH Heating foil Control unit Thermo sensor Transformer Please keep this document in a safe place...

Страница 3: ...etreatment of the substrate 08 3 2 2 Thermal insulation 08 3 2 3 Installation methods 09 3 2 4 Installation under tiles 09 3 2 5 Ceiling installation 10 3 2 6 Use in humid wet rooms 10 4 Electrical co...

Страница 4: ...stribution box In case of change of ownership the Please inform the subsequent owner about the installation In humid wet rooms DIN VDE 0100 part 701 be taken into account If the E NERGY CARBON heating...

Страница 5: ...or safety When working on the heating system the operating instructions must be handed over to the installer for information The E NERGY CARBON system can be installed inconspicuously in ceilings wall...

Страница 6: ...strip on the heating track must not be damaged or cut 2 4 Operation The E NERGY CARBON system impresses with its easy installation and operation To achieve the comfortable temperature the controller...

Страница 7: ...hnitte immer nur von der unkontaktierten Seite der Heizfolie vornehmen Jede andere unsachgem e Besch digung der Folie wie z B Einrisse durch scharfe Gegenst nde oder Knicke sind zu vermeiden Bewahren...

Страница 8: ...ceilings drywall panels and wood based panels must be installed to bridge cracks in the joint area When installing on the floor dry screeds and wood based panels must always be laid in two layers and...

Страница 9: ...ccording to installation method C it must be ensured that the heating strips are secured against slipping with adhesive tape and that a minimum distance of 20 mm is maintained between the individual f...

Страница 10: ...mmissioning must be carried out by a qualified electrician Attention If the measured resistance values deviate by more than 15 from the output value damage to the contacts or the heating foil must be...

Страница 11: ...on room thermostat 230 V L N SK N D heating circuit fuses 15 A each E Connection protective conductor for housing cover Figure 1 Example power supply unit BASIC TT 800 W AP UP C D E B A Network connec...

Страница 12: ...oltage variations Select the installation site taking into account the safety instructions and the following points of view carefully The maximum cable length between the heating track and the device...

Страница 13: ...s of the BASIC TT power supply unit are designed for the connection of a room thermostat with 230 V AC The room thermostat is connected to the room thermostat L supply terminal and room thermostat N s...

Страница 14: ...ilm Anschlussschema Connection scheme Basic TT 36 400W 800W 1200W AP UP DC Filter optional Netzanschluss Mains Supply 230V 50Hz Heizkreis Output S2 Heizkreis Output S3 Heizkreis Output S4 Heizkreis Ou...

Страница 15: ...Filter optional Netzanschluss Mains Supply 230V 50Hz Heizkreis Output S2 Heizkreis Output S3 Heizkreis Output S4 Heizkreis Output S5 Thermostat L N 230V 50Hz Last Load Max 400W N Max 400 W pro Heizkr...

Страница 16: ...erminal room thermostat N must be connected to the switching contact N L N PE L N N SK 36V 36V 36V 36V 36V 0V 0V 0V 0V 0V L N PE Heizkreis Output S1 Heizfolie Heat film Anschlussschema Connection sche...

Страница 17: ...in the immediate vicinity of the heating foil so that it is clearly visible and place the operating instructions in the distribution box or a suitable location Possible cause Remedy Heating mode not...

Страница 18: ...Internal safety temperature switch 130 C automatic resetting Insulation material class B Housing protection class IP20 Dimensions L x W x H 400 W 250x173x75 mm 800 W 300 x 220 x 85 mm 1200 W 300 x 22...

Страница 19: ...mum lengths hicoTHER hicoTHER hicoTHER Max heat transfer resistance R forfloor Explanation of symbols a Waste disposal instructions the product may n general household waste It must be recycled v wast...

Страница 20: ...199 06 99 53 516 00 262 80 188 30 0 2 m 182 92 99 53 49 77 258 00 131 40 94 15 0 3 m 121 95 66 35 33 18 172 00 87 60 62 77 0 4 m 91 46 49 77 24 88 129 00 65 70 47 08 0 5 m 73 17 39 81 19 91 103 20 52...

Страница 21: ...6 3 9 m 9 38 5 10 13 23 6 74 4 83 4 0 m 9 15 4 98 12 90 6 57 4 71 4 1 m 8 92 4 86 12 59 6 41 4 59 4 2 m 8 71 4 74 12 29 6 26 4 48 4 3 m 8 51 4 63 12 00 6 11 4 38 4 4 m 8 31 4 52 11 73 5 97 4 28 4 5 m...

Страница 22: ...7 3 m 5 01 7 07 3 60 7 4 m 4 94 6 97 3 55 7 5 m 4 88 6 88 3 50 7 6 m 4 81 6 79 3 46 7 7 m 4 75 6 70 3 41 7 8 m 4 69 6 62 3 37 7 9 m 4 63 6 53 3 33 8 0 m 4 57 6 45 3 29 8 1 m 4 52 6 37 8 2 m 4 46 6 29...

Страница 23: ...7 m 3 42 4 82 10 8 m 3 39 4 78 10 9 m 3 36 4 73 11 0 m 3 33 4 69 11 1 m 4 65 11 2 m 4 61 11 3 m 4 57 11 4 m 4 53 11 5 m 4 49 11 6 m 4 45 11 7 m 4 41 11 8 m 4 37 11 9 m 4 34 12 0 m 4 30 12 1 m 4 26 12...

Страница 24: ...FLEECE 66 W lfm 110 W m FLEECE 132 W lfm 220 W m FLEECE S 25W lfm 145W m FLEECE S 50W lfm 290W m PET 69 W lfm 115 W m 13 2 m 3 91 13 3 m 3 88 13 4 m 3 85 13 5 m 3 82 13 6 m 3 79 13 7 m 3 77 13 8 m 3...

Страница 25: ...r to have them repaired by a third party and to bear the costs incurred Furthermore mfh systems is entitled to de liver a comparable system from mfh systems or from a third party supplier as a replace...

Страница 26: ...___________________________ Elektroinstallateur Electrician _______________________________ Verlegedatum Fitting date _______________________________ Installationsdatum Installation date _____________...

Страница 27: ...nce after mounting 1 cm W m2 2 cm W m2 3 cm W m2 4 cm W m2 5 cm W m2 6 cm W m2 7 cm W m2 8 cm W m2 9 cm W m2 10 cm W m2 11 cm W m2 12 cm W m2 13 cm W m2 14 cm W m2 15 cm W m2 16 cm W m2 Resistance val...

Страница 28: ...RGY CARBON PET 69 W lfm 115 W m It is hereby confirmed that the above mentioned products comply with the essential requirements laid down in the Council Directive on the approximation of the laws of t...

Страница 29: ...29 heating foil assembled E NERGY CARBON room thermostats including temperature sensor and E NERGY CARBON power supply BASIC TT...

Страница 30: ...30 Notes...

Страница 31: ...31...

Страница 32: ...ystems GmbH Hager Feld 8 49191 Belm Vehrte Germany Fon 49 0 5406 699 95 10 Fax 49 0 5406 699 95 90 mail mfh systems com www mfh systems com Social Media Online download area LEAD FREE Im Einklang mit...

Отзывы: