20
E-NERGY CARBON FLEECE – 36 W/lfm (60 W/m²)
max. 11 m
E-NERGY CARBON FLEECE – 66 W/lfm (110 W/m²)
max. 6 m
E-NERGY CARBON FLEECE – 132 W/lfm (220 W/m²)
max. 3 m
E-NERGY CARBON FLEECE S – 25 W/lfm (145 W/m²)
max. 16 m
E-NERGY CARBON FLEECE S – 50 W/lfm (290 W/m²)
max. 8 m
E-NERGY CARBON PET – 69 W/lfm (115 W/m²)
max. 5,8 m
Per connection (output terminal pair 36 V) max. 400 W may be connected. The connected total power must not
exceed the rated power of the power supply unit.
The power supply unit can be installed surface-mounted or flush-mounted. Adequate ventilation must always be
provided. The ambient temperature must not exceed the maximum value of +40 °C.
The secondary cable between power supply unit and heating foil must not exceed 10 m at a cable cross section of
2.5 mm² and a maximum of 25 m with a wire cross-section of 6.0 mm².
Length
FLEECE
36 W/lfm
(60 W/m²)
FLEECE
66 W/lfm
(110 W/m²)
FLEECE
132 W/lfm
(220 W/m²)
FLEECE S
25 W/lfm
(145 W/m²)
FLEECE S
50 W/lfm
(290 W/m²)
PET
69 W/lfm
(115 W/m²)
0,1 m
365,84 Ω
199,06 Ω
99,53 Ω
516,00 Ω
262,80 Ω
188,30 Ω
0,2 m
182,92 Ω
99,53 Ω
49,77 Ω
258,00 Ω
131,40 Ω
94,15 Ω
0,3 m
121,95 Ω
66,35 Ω
33,18 Ω
172,00 Ω
87,60 Ω
62,77 Ω
0,4 m
91,46 Ω
49,77 Ω
24,88 Ω
129,00 Ω
65,70 Ω
47,08 Ω
0,5 m
73,17 Ω
39,81 Ω
19,91 Ω
103,20 Ω
52,56 Ω
37,66 Ω
0,6 m
60,97 Ω
33,18 Ω
16,59 Ω
86,00 Ω
43,80 Ω
31,38 Ω
0,7 m
52,26 Ω
28,44 Ω
14,22 Ω
73,71 Ω
37,54 Ω
26,90 Ω
0,8 m
45,73 Ω
24,88 Ω
12,44 Ω
64,50 Ω
32,85 Ω
23,54 Ω
0,9 m
40,65 Ω
22,12 Ω
11,06 Ω
57,33 Ω
29,20 Ω
20,92 Ω
1,0 m
36,58 Ω
19,91 Ω
9,95 Ω
51,60 Ω
26,28 Ω
18,83 Ω
1,1 m
33,26 Ω
18,10 Ω
9,05 Ω
46,91 Ω
23,89 Ω
17,12 Ω
1,2 m
30,49 Ω
16,59 Ω
8,29 Ω
43,00 Ω
21,90 Ω
15,69 Ω
1,3 m
28,14 Ω
15,31 Ω
7,66 Ω
39,69 Ω
20,22 Ω
14,48 Ω
1,4 m
26,13 Ω
14,22 Ω
7,11 Ω
36,86 Ω
18,77 Ω
13,45 Ω
1,5 m
24,39 Ω
13,27 Ω
6,64 Ω
34,40 Ω
17,52 Ω
12,55 Ω
1,6 m
22,87 Ω
12,44 Ω
6,22 Ω
32,25 Ω
16,43 Ω
11,77 Ω
1,7 m
21,52 Ω
11,71 Ω
5,85 Ω
30,35 Ω
15,46 Ω
11,08 Ω
1,8 m
20,32 Ω
11,06 Ω
5,53 Ω
28,67 Ω
14,60 Ω
10,46 Ω
1,9 m
19,25 Ω
10,48 Ω
5,24 Ω
27,16 Ω
13,83 Ω
9,91 Ω
2,0 m
18,29 Ω
9,95 Ω
4,98 Ω
25,80 Ω
13,14 Ω
9,42 Ω
2,1 m
17,42 Ω
9,48 Ω
4,74 Ω
24,57 Ω
12,51 Ω
8,97 Ω
2,2 m
16,63 Ω
9,05 Ω
4,52 Ω
23,45 Ω
11,95 Ω
8,56 Ω
2,3 m
15,91 Ω
8,65 Ω
4,33 Ω
22,43 Ω
11,43 Ω
8,19 Ω
*If the measured resistance values deviate more than 15 % from the initial value, damage to the contacts or the
heating foil. In this case you must not start up the heating system.
8. Resistance values as a function of length*
Содержание E-NERGY CARBON BASIC TT 1200
Страница 30: ...30 Notes...
Страница 31: ...31...