41
CHAPTER 4
Commissioning Loudspeakers Using the
Neuron ID Number
RMS-equipped Meyer Sound loudspeakers manufactured
in July 2003 and later display a label on the user panel
with the unique Neuron ID number of the RMS module.
This number can be used to commission the loudspeaker
without pressing the Service Pin.
To commission a loudspeaker using the Neuron ID number,
perform the following steps:
1. Ensure that the loudspeaker is powered on and con-
nected to the host computer.
2. After launching RMS, open the minimized Network
Server and Manager by clicking on it in the Windows
Taskbar.
3. Click
Network Manager
from the menu bar to open
the RMS Network Manager. The RMS Network Man-
ager appears, showing your RMSNET network and
any i.Lon-10 networks you may be using. Highlight the
network that the loudspeaker is on.
4. Click the
Device Mgr
button to open that network’s
Device Manager. Any loudspeaker nodes commis-
sioned on that network will appear.
NOTE:
If no loudspeakers have been com-
missioned onto the network, the host should
be the only item listed in the Device Manager.
5. Enter a unique Device Name (not the Neuron ID) into
the Device Name field. Click the Add Device button.
The Loudspeaker Identification dialog appears.
6. Enter the loudspeaker’s Neuron ID. Click the
Use ID
button.
7. Choose RMS3 or Prod6h from the drop-down box,
then click the
Commission
button. The RMS applica-
tion will search the network for the Neuron ID number;
once found, it will commission the loudspeaker into the
network database.
Repeat the above steps for each loudspeaker you wish
to add using the loudspeaker’s Neuron ID. When you’re
finished, close the Device Manager and Network Manager
windows, minimizing the Network Server and Manager
to the Windows Taskbar. Add your newly commissioned
loudspeakers using the procedure outlined in the Device
Names in the Network Database section in this chapter.
NOTE:
If the commissioning fails, double-
check the following:
■
The loudspeaker must be powered on and prop-
erly connected to that network.
■
The Neuron ID number must match the one shown
on the Neuron ID label on the loudspeaker.
■
If you’re using multiple networks, make sure
you’re working in the correct Network Device
Manager.