![Meyer Sound RMS 4.5 Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/meyer-sound/rms-4-5/rms-4-5_user-manual_1781732024.webp)
20
CHAPTER 2
2. Remove the four Phillips-head screws from the blank
perforated plate or RMS communications module if
installed and being replaced. Save the plate in case
you need it in the future.
3. Make sure the copper strip on the left-hand side of
the opening is properly positioned and not damaged.
This strip contributes to the grounding of the RMS
communications module to the chassis. If you need to
replace the strip, please contact Meyer Sound.
4. Look for the ribbon cable underneath the Audio
Input module. Connect and lock this cable to the
RMS communications module. Slide the RMS
communications module into the power supply
module, hand-thread the four screws into place, then
tighten the screws until they are flush and secure.
NOTE:
Be very careful to avoid touching
any of the components. Always handle
modules by their edges.
5. After installing the RMS communications module,
power-up the loudspeaker. The Activity LED will blink
to indicate that the new RMS hardware is operational
and ready to be commissioned on your network.
NOTE:
All modules are shipped
commissioned to Meyer Sound’s network.
In the rare case that the Service LED blinks, this
does not mean that there is any problem with the
card and/or electronics. It indicates that the RMS
module was reset and needs to be commissioned.
In order for RMS to communicate with the module,
please commission the replacement/upgrade
module to your network (as discussed in Chapter 3
of this guide).
screws
copper strip
locking
connector
Содержание RMS 4.5
Страница 1: ...USER GUIDE RMS 4 5...
Страница 28: ...24 CHAPTER 2...
Страница 56: ...52 APPENDIX A...
Страница 60: ...56 APPENDIX B...
Страница 62: ......
Страница 63: ......
Страница 64: ...2004 Meyer Sound Laboratories Inc 05 033 302 02 A...