20
| i5000™ MetroMark™ Manual
Doc. No.:
R12015
Metrotech Copyright © 2008
Figure 5-10 Data Logging Depth Measurement Interface
For passive power and radio frequency locating, only the peak antenna is used and displayed.
Figure 5-11 Passive Power Operational Interface
5.2 Marker Locating Mode:
The i5000 MetroMark is equipped to locate passive and active buried electronic markers. If these electronic utility
markers are known to be buried underground, the i5000 MetroMark can be easily converted with a softkey func
-
tion to transmit a signal pulse from the receiver down to the ground. This signal pulse for a single utility activates
the buried marker that in turn generates a magnetic field response detected by the receiver.
Each marker, depending upon the utility type, emits a specific frequency signal. The frequency emitted by utility
type is listed below.
Utility Type
Color Icon
Frequency (Hz)
Non-Potable (NP) Water
66.35K
Cable Television (CATV)
77.0K
Gas
83.0K
Telecommunications
101.4K
Waste Water (Sanitary)
121.6K
Water
145.7K
Power
169.8K