Metrotech Corp. |
5
Metrotech Copyright © 2008
Doc. No.:
R12015
43.0
dB
491Hz
Auto
Back
Mark
Depth
Current
0’ 5” 5.7
mA
▼
Figure 2-4 Depth & Current Measurement Screen
2.2 Switching to Marker Locate Mode
6)
Press the Menu softkey and 4-way navigation button to access the Shortcut Menu list. Select the line
locate/marker switch shortcut from the menu list to easily switch from line and marker locate modes from the op
-
erational interface.
7)
Press the Type softkey to choose the desired electronic utility marker to be detected.
8)
Observe the signal strength to detect and determine the location of a buried marker. The maximum signal
strength will indicate the location of the buried marker.
9)
Press downward on the 4-way navigation to calculate marker depth.
Type
Gain
Menu
LL
90.7
dB
Gas
Auto
e
Selected Marker Type to be Located.
f Volume Level in Use.
g
Battery Level.
h
Signal Strength.
i
i5000 Soft Keys.
Marker Type Description.
d
Marker Type Icon.
c
Auto/Manual Gain Mode.
b
Peak Signal Bar Graph.
a
Figure 2-5 Marker Locate Mode