METRODATA LTD
WCM1100 / WCM3100 / WCM-Serial
User Manual
76-02-082 Rev J
120 of 140
5.5.8.1.1.6 put Report
For units that support SAM service validation tests, the put report option will allow the
generated service birth certificate to be uploaded. This is not supported on the WCM
units.
5.5.8.1.2 Server Mode
Select SERVER mode to display the menu as below:
Metrodata WCM "" Alarms: Major
TFTP
Mode Server
remote IP 192.168.100.70
Software file name software
Config. file name config
First CAPITAL - select item
<escape> - exit menu
In server mode, the transfer is initiated from an external client. If the file downloaded
matches that configured for Software or Config then they will be used to upgrade the
software or configuration.
To use TFTP, the IP address of the remote server must be entered.
For security reasons, it is recommended to change the default settings for software and
config file names to prevent unauthorised updates.
To initiate a TFTP transfer from a windows PC, select a DOS window and then type the
command
tftp
–i “WCM IP Address” put “Source Filename” “Software File Name”
eg
tftp
–i 192.168.0.1 put wcm1100.812 software
Which will load a file named
“wcm1100.812” onto the WCM with IP address 192.168.0.1
and load as a file called
“software”