Multi LAN 350
Operation
62
5.11.1 Saving the latest PLOTS
The plots of the latest:
- NEXT and Remote NEXT,
- PSNEXT and Remote PSNEXT
- ELFEXT and Remote ELFEXT
- Attenuation
- Return Loss and Remote Return Loss
- ACR and Remote ACR
- PSACR and Remote PSACR
- TDR
- TDnext
Tests are automatically stored in a reserved memory place (reserved by default) and
can be downloaded to a PC and analysed with LANlink.
Each of the plots will stay in memory untill a new measurement will be performed.
Note:
The plot data will be lost:
- when the batterie is empty
- the batteries are removed
- when changing the batteries
Refer to Section IV for further information about downloading, documentation and
analysis of plots.
5.11.2 Saving Complete Autotest / Near End Autotest / Remote
Autotest results
In the MEMORY menu the MultiLAN 350 memory structure is displayed. The structure
is divided into three numbered levels that define a location. The level names used are
OBJECT, FLOOR and CABLE. Each location has assigned all three level attributes to
enable the operator to store the results as logical manner as possible.
All objects, floor and cable numbers can be set between 000 and 200. In the upper right
corner of the screen the remaining memory place (in percents) is displayed.
When saving new Autotest result the CABLE number is automatically increased
(OBJECT and FLOOR remains the same as previous) and offered for confirmation
(CABLE is flashing).
In each location one Complete Autotest can be stored.
Saving Autotest results for copper cables:
A Complete Autotest can be composed from one Near End Autotest and one Far End
Autotest (to allow complete cable verification when working with the Remote Unit
MultiLAN350 RU). Refer to chapter 5.5.2 for more information about Autotest types.