General specifications
20
4 General specifications
4.1 General Data
Instrument MultiLAN 350
Autotest time:
55 sec, standard CAT6 test
Display:
LCD Graphic type, 320 x 240 dots, EL backlight
Memory: 500 Autotests typical
Copper and/or fiber
Operating temperature range:
5
°
C
÷
40
°
C (intrinsic accuracy is specified at 25
°
C)
Storage temperature range:
0
°
C
÷
70
°
C
Relative humidity:
85 % up to 40
°
C declining to 70 % up at 45
°
C non
condensing
Pollution degree:
2
Protection degree:
IP40
Power supply main unit:
6 x 1.5 NiMH type C rechargeable batteries
Charger/External supply input:
12 V – 15 V,
Charging time:
12 hours
Typical battery life:
8 hours
Memory backup:
unlimited
Communication:
RS232 serial interface for connection to a PC.
Selectable 2400 -115200 baud. 9 pin D connector.
USB connection to a PC.
Auto Off time: 10 min
Remote Unit MultiLAN 350 RU
Operating temperature range:
5
°
C
÷
40
°
C
Storage temperature range:
0
°
C
÷
70
°
C
Relative humidity:
85 % up to 40
°
C declining to 70 % at 45
°
C (non-
condensing)
Pollution degree:
2
Protection degree:
IP40
Power supply:
6x1.5 LR14 alcaline or rechargeable batteries
Charger/External supply input:
12V – 15V
Charging time:
12 hours
Typical battery life (alkaline batteries): 15 hours
Communication:
RS232 serial interface for connection to a PC.
Selectable 2400 - 115200 baud. 9 pin D connector.
Auto Off time:
10 min
Cable wiring standard: T568B
Pair 1:
wire 5, blue-white
wire 4, blue
Pair 2:
wire 1,orange-white
wire 2, orange
Pair 3:
wire 3, green-white
wire 6, green
Pair 4:
wire 7,brown-white
wire 8, brown