Multi LAN 350
Operation
56
ESC key:
return to the Test Standard screen. New settings are not
considered.
Up, Down:
select the cable type
Enter:
Enter the NVP setup menu
Cable Type screen
5.7.3 Setting cable NVP
Cable NVP can be set in this screen. It is recommended to use this option if the exact
cable NVP is known.
In the upper rows the actual test standard, cable type and NVP are displayed. The
following actions can be performed:
ESC key:
return to the Cable type screen. New settings are not considered
Up, Down:
select the NVP value. Default NVP value for the selected cable type
is offered as the initial value.
Enter:
Enter the Autotest Tests menu
Cable NVP screen
5.7.4 Autotest sequence configuration
In this screen the tests attributed to the selected test standard are displayed. Whichever
measurement can be set On or Off manually.
For each selected standard, the tests that have limits applied for the selected cable
standard are set On by default.