Multi LAN 350
Operation
52
In the table below the 8 measurement test organization is shown:
No. of
test
Measurement Cable
Wavelength Device on
the near
side
Device on the far
side
1
A
850nm
optical
power meter
optical source
2
B
850nm
optical
power meter
optical source
3
A
850nm
optical
source
optical power meter
4
B
850nm
optical
source
optical power meter
5
A
1300nm
optical
power meter
optical source
6
B
1300nm
optical
power meter
optical source
7
A
1300nm
optical
source
optical power meter
8
B
1300nm
optical
source
optical power meter
5.6.2 Testing procedure
Make sure that the FIBER OPTICAL cable type is set and the IR adapter is inserted in
the instrument. Set AUTOTEST with rotary switch.
Check if Cable standard, Cable type, No. of adapters, No. of splices and length are set
correctly.
The Test standard and belonging parameters can be changed in the TEST STANDARD
menu. Refer to chapters 5.8 for more information.