6
BGA-3500 Series Manual 5/01
Main Unit Components - Figure 1
1
1. Open Frame adjustable printed circuit board holder.
1
2. Main Power Switch.
1
3. Subzone heater, heat/cool selector switch.
1
4. BGA-3528 Micro Oven Head Assembly
1
5. Z-Axis Adjustment Lever – Rotating Clockwise will raise the head assembly, while rotating
counter clockwise will lower the head assembly.
1
6. Component Pick-up Solenoid – When engaged, the vacuum is set to automatically raise the
component after reflow.
III. SYSTEM FUNCTIONS
BGA/CSP-3500 SYSTEM - Figure 1 (page 7)
1
7. Vacuum Cup Height Lock – After the lift solenoid has been armed, this knob locks the vacuum cup
into position on the component to be removed.
1
8. Quick-change Nozzle Release / Lock Mechanism
1
9. Nozzle Rotation Knob – Adjusts the angle at which the nozzle sits in reference to the component
10. Board Holder Position Locking Knob – When placing a component, pull this knob towards you
and slide the board holder until it locks securely underneath the Placement arm or reflow head.
11. Underboard Support Assembly– Provides support to the printed circuit board and reduces any
potential of PCB warpage or bowing. Adjust the 4 thumbscrews on the underboard support until
they contact the bottom of the PCB and provide support.
This underboard support is constructed of a special material that reduces the absorption of heat,
however, in some instances it may interfere with the transfer of heat energy from the underboard
heater. Please position it away from the component under rework.
12. X-Axis Lock / Unlock Bar – Set into the “horizontal” position to unlock the X-Axis to make coarse
adjustments, and then set into the “vertical” position to lock the X-Axis to make fine adjustments
using the micrometer.
13. Y-Axis Lock / Unlock Bar – Set into the “horizontal” position to unlock the Y-Axis to make coarse
adjustments, then set into the “vertical” position to lock the Y-Axis to make fine adjustments using
the micrometer.
14. X-Axis Micrometer - Used to make fine adjustments to the X-Axis.
15. Y-Axis Micrometer - Used to make fine adjustments to the Y-Axis.
16. Vacuum Contact LED – Illuminates when the removal vacuum is activated AND the vacuum
pad is
in contact with the component.
17. Component Illumination Knob –Varies the amount of light directed to the bottom side terminals of
the component. This adjustment affects the illumination of the component viewed on the monitor.
18. PCB Illumination Knob - Varies the amount of light directed to the top of the PCB. This adjustment