28. Calibrate Servo Drives
The Servo Drive option can be selected on
the top of the screen when an axis is
selected in the Axis.
Port:
This is the port that the PC will use to
communicate with the Servo, to setup the
port see the Calibrating Ports help file.
Address:
This is the address that is assigned to the
servo, to distinguish it from the other Servo
Drives or PLCs on the same port.
Actual Position:
This is the position that the Axis connected to the servo drive is currently at (measured in mm).
Calibration Factor:
This is the factor used to convert from the Servo Drives encoder pulses to an actual measurement
(mm per pulse).
Full Rotation:
The number of encoder pulses in a full rotation of the Servo Motor.
Tollerance:
This is the tolerance of the measurement from the Servo Drive.
Fast Speed:
This is the speed the Servo Motor moves at provided it is not close to the target.
Slow Speed:
This is the speed the Servo Motor moves at when it is close to the target.
Servo Settings:
This is used to set up the Servo Drives with defaults
from Fasfold.
Note: Each of these options requires the Servo Drive
be reset (turned off and then on) to take effect.
Note: It is recommended that you complete the
operations in this order.
Factory Defaults:
This option resets the Servo Drive to the Factory
Default settings.
Page 20
Instruction Manual For Fasfold Controller
04/12/2014