30
7.
PNP light curtain
8.
Pass door / Slack cable / cable breakage X12
9.
Safety edge
WARNING
In case of fire, the door will remain open for max. 120 sec. If the safety feature is still activated,
the door will close without the safety feature.
LIGI 01 PNP light curtain X11
Description
Transmitter
X11-1 = Brown
X11-2 = Blue
X6-4 = 24 vdc
X6-5 = Black
Recipient
X11-1 = Brown
X11-2 = Blue
X11-3 = Black
Connect both white wires
to each other
Pass door / Slack cable / cable breakage X12 Connect
X12 is an input that features a stop function. This input
can be used to connect the contact for the pass door and
the slack cable switch. This is connected in series as an
N.C. contact with a 5.1KΩ resistor. If there are several
normally closed contacts, they must be placed in series
and a 5.1KΩ resistor must be placed on the last contact
so that a short-circuit in the connecting cables will not
have an impact on this input. If this input is not used, a
5.1KΩ resistor must be placed between connection 1 and
2.
Safety edge X13
Pneumatic safety edge (1K2)
Electric safety edge (8K2)
Optical safety edge