background image

 

 

 

 

 

 

7

 

 

6. 

Spare parts ............................................................................................................................ 57 

7. 

Installation details (to be filled in by the installation engineer) ........................................... 58 

8. 

Maintenance sheet ............................................................................................................... 59 

 

Содержание FirePro V4

Страница 1: ...User manual FirePro V4 Type HW V4 4 SW V5 2 Version 20220628 PLEASE CAREFULLY READ THIS USER MANUAL BEFORE YOU USE THE CONTROLLER STORE THIS INFORMATION SO THAT IT CAN BE REFERENCED IN THE FUTURE...

Страница 2: ...can be revised if necessary No rights can be claimed from the provided information All rights reserved All mentioned trademarks are the property of their respective owners No part of this publication...

Страница 3: ...applicable legislation be retained for reference purposes until the controller is disposed of Make sure that this user manual is within reaching distance of people who come into contact with the cont...

Страница 4: ...N Indicates a dangerous situation that if safety related instructions are not followed could result in a minor to moderate injury and or damage to the controller or the surroundings WARNING Indicates...

Страница 5: ...4 4 Safety 17 4 1 Safety systems 17 4 2 Safety arrangements 17 4 3 Specific safety guidelines 17 4 4 Meaning of warning signals 18 4 5 Signs and symbols 19 5 Transport and storage 20 5 1 Transporting...

Страница 6: ...y settings 40 8 8 Parameter series 4 warning settings 41 8 9 Parameter series 5 output settings 43 8 10 Parameter series 8 maintenance settings 45 8 11 Parameter series 9 registration 45 9 Error Messa...

Страница 7: ...7 6 Spare parts 57 7 Installation details to be filled in by the installation engineer 58 8 Maintenance sheet 59...

Страница 8: ...sioning maintaining and inspecting the controller The controller must be installed in the immediate vicinity of the door that is to be operated A good view of the door opening must be guaranteed when...

Страница 9: ...f the controller endanger the safety of the user or other people reduce the life span of the controller nullify compliance with CE guidelines It is forbidden to use the controller for a purpose other...

Страница 10: ...ectricity Max 8 3 A Brake 24 Vdc Control voltage 24 Vdc Control current 300 mA External power 24 Vdc Current external power Max 500 mA Relay outputs potential free changeover switches Load of relay co...

Страница 11: ...11 2 Description 2 1 Front view Figure 3 Front view Table 2 Layout front view No Component 1 Casing 2 Signal transmitter 3 Front panel 4 Cable inlet 4 x M16 5 Ventilation 6 Lock 7 Cable inlet 2 x M20...

Страница 12: ...er charger and 2 batteries 12V 5 2Ah The lid of the cabinet has a control panel that features 4 status LEDs Figure 4 Internal view Table 3 Layout internal view No Component 1 Casing 2 Ventilation 3 Fi...

Страница 13: ...or automatic operation Operation via panel on cabinet lid or external controls Status display via 4 LEDs on cabinet lid Buzzer with mute function Fire alarm input Smoke and heat alarm input Input for...

Страница 14: ...f they become completely empty In this case replace the batteries Disconnect the battery connection if the door is in a safe position WARNING If the drive unit has mechanical limit switches an interim...

Страница 15: ...door closes during emergencies An output is present for connecting an extra signal transmitter It is possible to connect a safety edge This can be done using a safety feature with potential free rela...

Страница 16: ...of a fire alarm if mains power is still present to allow someone to escape The door will close again after a configured time There is also a setting that allows the door to be opened again with the o...

Страница 17: ...included in the technical dossier of the electrically powered door This must be compiled by a professional installation engineer 4 3 Specific safety guidelines Safe use of this controller can only be...

Страница 18: ...again after all maintenance activities and other interventions ENVIRONMENT Comply with local legal requirements for all products that are used in the controller and for all products used to maintain...

Страница 19: ...Switch off buzzer Factory setting CAUTION Make sure that the pictograms are visible at all times Clean the pictograms on a regular basis and replace them in case of wear and tear No Warning signal Sy...

Страница 20: ...nts at the configuration location 5 2 Storing the device for a long period Environment temperatures above 40 C or below 5 C during use or above 40 C or below 15 C during storage can have an impact on...

Страница 21: ...rews have be properly tightened and that everything has been connected correctly The installation engineer must compile a risk analysis for the whole installation In this case make sure the door in qu...

Страница 22: ...22 The installation engineer must hand over a fully completed and signed inspection report to the end user Figure 5 Assembly instructions...

Страница 23: ...23 7 Commissioning Figure 6 Circuit board FirePro V4...

Страница 24: ...Com 4 No X12 Pass door slack cable cable breakage resistor or NC contact 1 Com 12 Vdc 2 NC 5k X13 Safety edge 1 12 Vdc Max 50 Ma 2 Resistor 1K2 8K2 3 Opto 4 GND X14 Transmitter LIGI 07 OSE light curt...

Страница 25: ...f this is the case the controller can be easily modified or reset The controller can only be configured effectively via the menu once the end positions have been set 7 2 Configuring end switches NES T...

Страница 26: ...4 1 and 4 2 As intermediate position switch if opting for half open in case of fire alarm parameter 4 3 Configure this end switch at the position where the door must stop in case of fire alarm smoke...

Страница 27: ...position is set as standard at the same position as the saved end position closed Use parameter 1 7 to configure this position at the position where the door must stop in case of fire alarm smoke ala...

Страница 28: ...operly if connected incorrectly Brake interruption X4 Connect A switch can be connected to X4 in order to cut the 24 VDC supply voltage to the brake In emergencies this switch can be used without acce...

Страница 29: ...fety feature Potential free contacts X6 Connect X6 features two outputs as potential free changeover switches They can be configured for various functions via parameters 5 1 and 5 2 Programmable input...

Страница 30: ...ack cable cable breakage X12 Connect X12 is an input that features a stop function This input can be used to connect the contact for the pass door and the slack cable switch This is connected in serie...

Страница 31: ...to connect external UP STOP DOWN controls If X16 is not used connect terminals 1 and 2 stop function using a wire bridge There is also an input for an external mute button Inputs X17 Connect Inputs fo...

Страница 32: ...s the option of resetting one or both fire alarms in order to return to normal operation This can be done by connecting a push button at X18 3 and X18 4 as potential free normally open contact N O con...

Страница 33: ...ntrol panel is connected to connector X21 using a flat cable RJ 45 Connector X22 Connect RJ 45 connector for connecting a future expansion of the RDA Updater DES NES X23 Connect The end switches of th...

Страница 34: ...able FirePro V4 Number Description 1 Cable 2 DES NES connector 3 Phase connector drive unit 4 Brake connector drive unit 5 Wire end ferrule 6 DES NES pin for connector 7 Cable gland 8 Cable inlet rubb...

Страница 35: ...red before the menu can be accessed the default is 99 can be modified in menu 9 6 Once the password has been entered the menu will remain accessible for 10 minutes without requiring a password Start p...

Страница 36: ...y edge activation X 2 Stop if safety edge is activated and only continue if the close button is pressed again 0 5 Safety edge function during fire alarm only if par 0 4 2 1 Photocell off Safety edge o...

Страница 37: ...time parameter 0 6 0 6 Delay activation of safety edge protection in case of fire 0 60 Seconds 3 sec 0 7 Safety edge function within range pre end switch 1 Stop if safety edge is operated X 2 Deactiv...

Страница 38: ...end position closed Increase or decrease closed position 0 to 9 1 5 Adjust pre end position Select the desired door position and save using stop ok button Stop button on lid to cancel 1 6 Fine correc...

Страница 39: ...tion X 2 Switch operating buttons on off 3 Works as mute function 4 Input for key switch to bring door back to intermediate position if this has overrun after power failure only possible for DES Pleas...

Страница 40: ...edge photocell operated during emergency 0 to 10 The total will be indefinite if this parameter is set to 0 0 3 6 Action if safety edge and or photocell are not detected when the FDC SDC or door clos...

Страница 41: ...ng time for interim stop Par 4 1 2 1 to 240 seconds 1 sec 4 3 Choice door movement in case of fire alarm NES partial opening extra end switch S6 Par 3 2 2 DES configure intermediate position in parame...

Страница 42: ...d 2 4 7 Delay time door release after reset 0 to 240 seconds 60 sec 4 8 Activating half open in case of alarm emergency Must only be set for DES Par 4 9 1 Deactivated door opens fully when escaping du...

Страница 43: ...t curtain 8 Test function for wireless transfer system on safety edge protection 9 Battery error from power charger 1 0 Low battery voltage 1 1 Safety edge activated faulty 1 2 Photocell safety featur...

Страница 44: ...etection 1 to 60 minutes 1 min 5 5 Function LED buzzer signal transmitter 1 For all error messages and fire alarm emergencies Only activate again after longer than 30 seconds for photocell and or safe...

Страница 45: ...reaching 0 a message is sent to perform maintenance 8 11 Parameter series 9 registration Parameter Description Settings 9 1 Cycle counter Number of times door has opened cannot be reset 9 2 Last 20 er...

Страница 46: ...remove one of the detectors in the chain from the socket F 1 6 Input for safety brake activated Check switching contact and or cables safety brake F 2 0 No safety edge present or safety edge faulty T...

Страница 47: ...ctly configured and if the safety edge rubber is pressed hard enough when the door is closed F 2 9 Opto sensor activated The safety edge opto or OSE light curtain have been broken This could be attrib...

Страница 48: ...oor movement Check the door mechanism Check the phases to the drive unit U V W Check the rotation movement digital end switch Door movement only still possible with internal push buttons Note Door end...

Страница 49: ...r and re connect them after 30 seconds If this is as it should be replace the controller F 7 8 Error in inversion circuit Tested for each end position This error message is generated if one of these r...

Страница 50: ...seconds The fire detection function can be extended once the FDC input has closed again This can be configured to between 0 and 240 seconds via parameter 3 4 An input is available for connecting the...

Страница 51: ...s with a smoke gasket One of the potential free contacts must be configured so that it is activated if the door is closed via the fire input s where the gasket must be inflated This involves options 2...

Страница 52: ...User Visual inspection controller Inspection Yearly Installation engineer Visual inspection drive unit Inspection Monthly User Visual inspection drive unit Inspection Yearly Installation engineer Vis...

Страница 53: ...ant button is operated and make sure it does not make any strange noises 7 Functional inspection Safety components Operate the installed safety components photocell light curtain safety edge protectio...

Страница 54: ...ctioning operation maintenance etc of the controller as described in this user manual DANGER It is forbidden to remove bypass or deactivate safety features and protective devices 12 2 Disposal The sym...

Страница 55: ...ances Safety Part 1 General requirements EN 61000 6 2 2019 Electromagnetic compatibility EMC Part 6 2 Generic standards Immunity standard for industrial environments EN 61000 6 3 2021 Electromagnetic...

Страница 56: ...2 4 2 n a 4 1 2 8 4 n a 1 2 4 1 yes 2 1 4 1 2 8 5 n a 1 2 4 2 no 2 1 1 n a 4 1 3 n a 1 2 4 3 n a 2 1 2 n a 4 2 1 2 4 4 n a 2 2 4 2 1 n a 1 2 5 yes 2 2 1 n a 4 2 2 n a 1 2 6 yes 1 2 2 1 1 n a 4 2 3 n...

Страница 57: ...ption Additional information FirePro V4 control circuit board HWx xx Power charger 24 Vdc battery 12 Vdc 5 2 Ah Panel key Indicator buzzer P cap V2 Velcro 400 x 30 mm flame retardant Fuse F1 6 3 Amp r...

Страница 58: ...ufacturer Name Address Telephone number Email Website Details installation engineer Name Address Telephone number Email Website Details Controller Manufacturer Product number Serial number Software ve...

Страница 59: ...59 8 Maintenance sheet Date Done by Maintenance done...

Страница 60: ...60 Your installation engineer Metacon Next B V Zuidbaan 450 2841 MD Moordrecht T 31 0 182 23 15 25 E service metacon next com...

Отзывы: