background image

E

D

R4 117

9 G2.16 10/03

2

Important safety instructions for
installation

To prevent fire or shock hazard, do not expose the opener to rain or moisture.
To avoid electrical shock do not open the cabinet without disconnecting the opener from the mains.

WARNING Incorrect installation can lead to severe injury. Follow all installation in-

structions.

Garage doors are under great spring tension. Do not attempt to adjust spring tension. Do not
loosen any brackets under spring tension. Do not remove springs from the door. Merlin does not
accept responsibility for damage or injury resulting from installing this opener. Unless you have
appropriate training, refer door adjustments to the door manufacturer.
To avoid difficulty during installation, do not connect the opener to the mains or run the door opener
until instructed to do so.
Do not use force sensitivity adjustments to compensate for a binding or sticking garage door.
Excessive force may damage the garage door.
Before installing the drive remove all unnecessary ropes or chains and disable any equipment, such
as locks, that is not needed for powered operation.
Before installing the drive check that the door is in good mechanical condition and that it is cor-
rectly balanced. Check that it opens and closes properly.
Install the actuating member for the manual release (red handle on a rope) such that it rests at a
height of less than 1.8 m.
Install any fixed control, wired or wireless, within sight of the door but away from moving parts and
at a height of more than 1.5 m.
Install the drive such that all moving parts (except the door and the manual release) are at a height
of more than 1.8 m.
Permanently attach the label warning against entrapment in a prominent place, or near any fixed
control.
Permanently fix the label concerning the manual release adjacent to its actuating member (thread
the cord through the holes in the manual release warning card).
After installation, ensure that the mechanism is properly adjusted and that the drive reverses when
the door contacts a 40mm (50mm for UK) high object placed on the floor.
The appliance is not intended for use by young children or infirm persons without supervision.
If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a
similarly qualified person in order to avoid a hazard.

CE compliance after installation (EC countries only)

It is the responsibility of the installer of the opener to ensure that the forces measured at the
leading edge of the door are within the guidelines of BSEN 60335-2-95:2001. This may require
adjustment of the drive and may also require adjustment of the door. Specialised measurement
equipment may be required. Contact Merlin for assistance if necessary. If the measured forces
exceed the guidelines then Merlin M102 non-contact sensors must be fitted.

Содержание prolift 230T

Страница 1: ...EDR4 1179 G2 16 10 03 1...

Страница 2: ...release red handle on a rope such that it rests at a height of less than 1 8 m Install any fixed control wired or wireless within sight of the door but away from moving parts and at a height of more...

Страница 3: ...n doubt about whether the door is suitable for automation consult Merlin Tilt door clearances The opener has been designed to fit most existing doors The minimum installation clearance from the garage...

Страница 4: ...econds 60 seconds and 90 seconds For a 30 second delay autoclose short ON For a 60 second delay autoclose long ON For a 90 second delay both short and long ON NOTE Auto closing will only work if the b...

Страница 5: ...se the Chain on the smaller of the two sprockets STEP 5 Thread up the chain The threaded end of the torpedo should now be pointing back toward the power head Additional setup for trackless tilt doors...

Страница 6: ...d mark this maximum door height onto the header above the top edge of the door On tilt doors with tracks this maximum height might be as low as the top edge of the closed door If a sectional door tors...

Страница 7: ...ener Check that the door does not hit the pole when manually open ing and closing Allow a minimum of 25mm clearance between the top edge of the door and the bottom of the pole Attaching the return pul...

Страница 8: ...the straight arm is all that is required on tilting doors Usually the L arm is attached between the door and the straight arm for use with sectional doors You may have to shorten or re drill the door...

Страница 9: ...wire to the power head Connect the wire to the two terminals inside the wall control box Mount the box to the wall CAUTION Keep the push button cable at least 60mm clear of mains power cables if it i...

Страница 10: ...stay on continuously at the fully closed position The green LED will stay on continuously at the fully open position Identify the green operate button Ensure the door is engaged on the trolley STEP 3...

Страница 11: ...trol panel cover STEP 2 Identify the green and the red control knobs marked open force and close force Note The opener can be set to either determine its own safe operating force level or it can be se...

Страница 12: ...t s underside Remove the green control panel cover to expose the setup controls Identify the red learn button To learn a remote button to operate the opener Press the learn button for 1 2 seconds unti...

Страница 13: ...have several openers that operate from this master remote then all these openers will begin to flash their courtesy lamps Press the button on the master remote that would normally operate the opener...

Страница 14: ...t The high level of Infra Red light in bright sunlight may temporar ily prevent normal operation of the opener Switch off the power to the opener Run the pair of cables from each sensor back to the ac...

Страница 15: ...le and strapping Trolley speed depending on sprocket and load 75 to 135mm sec Rated force 770N Standard pole length 2750mm to suit chain supplied Standard assembled overall length pole length 400mm 31...

Страница 16: ...on Some features or accessories may not be available in certain markets or areas Please check with your distributor Merlin service centres New Zealand Auckland phone 09 415 4393 Phone toll free 0800 6...

Отзывы: