E
D
R4 117
9 G2.16 10/03
9
STEP 17:
If a wall control box is included in
your opener then locate a conven-
ient position to mount the wall con-
trol box. The garage door should be
visible from this location. There
should be no moving parts of the
door or opener within 1.8 metres of
this box and the box should be
placed higher than 1.5 metres from
the floor.
Connect the wire to the manual con-
trol accessory terminals on the rear
of the power head. Take care to keep
frayed wire ends from shorting
across terminals.
Route wire from the power head to the location for the wall control box. Allow some slack in the
wire to the power head. Connect the wire to the two terminals inside the wall control box. Mount
the box to the wall.
CAUTION Keep the push button cable at least 60mm clear of mains power cables if it is
parallel to them. Do not run the push button wiring through the same cavities in the wall as
the mains power. Mains and low voltage wiring can cross with no problems.
STEP 18:
Remove or disable any door locking mechanism. Remove unnecessary ropes or chains
STEP 20:
Fit the light cover into position and lock the cover securely.
STEP 21:
Manually raise the door and re-engage the trolley.
STEP 22:
Attach the red release rope through the hole in the trolley release lever. The handle
must be fitted at a height of less than 1.8 metres.
Ensure the release cord is threaded through the manual release warning card.