G915
D
May 05
16
Controls
IMPORTANT
If the force/speed/voltage setting (+FOR-) is adjusted then it is necessary
to perform either Easy Setup or Professional Setup again because the travel times will
vary. Failure to do this risks causing damage to the gates or gate stops.
After every trimmer adjustment press RESET to confirm the change. Wait for the LED to
stop flashing.
reset button (RESET)
Pressing RESET has the same effect as interrupting the power supply. It will stop the
movement of the gates. The yellow LED will flash for five seconds and then the board will
be ready to operate. No memory settings are altered when RESET is pressed. No learned
wireless transmitters are removed from memory.
enable testing of safety devices
jumper (TEST)
GT/SYSTEM hand held
programmer connection
force/speed/voltage 50 to 100%
(+ FOR -) (cw max voltage)
auto close pause 3 to 60 sec
(+ PAU -)(cw OFF)
obstruction sensing delay
0.1 to 2.5 sec
(+ OBS -) (cw max time)
professional setup /
learn wireless control button
(P2/RADIO)
learn wireless pedestrian access
jumper (CH-RADIO)
easy setup button (P1/SET)
(Press after any
trimmer adjustment)
motor leaf delay 3 to 30 sec
(+ DEL -) (cw max time)
reset button (RESET)
(press after adjusting
any trimmer)
enable lock strike delay
jumper (STRIKE)
Содержание G915D