11
Make all connections
NOTE
When powering any accessories from the board, (for example: gate latches,
additional receivers, keypads, PE beams) ensure the total combined load on the VA and
TXF terminals does not exceed 150 mA. If necessary, remove accessories or provide
additional power supplies directly to each accessory.
transformer input
Can accept 12 or 24 V ac, max 100 VA, max 10 A.
NOTE
The transformer must have sufficient capacity to maintain motor voltage above 10
V (or above 20V for 24V systems).
battery input
A 12V 1.2 Ah sealed back-up battery is recommended, and should result in sufficient
capacity for at least five full operations in the first 24 hours of any mains supply failure.
transformer in
transformer in
battery in - ve
battery in + ve
motor 1 out (first to open)
motor 1 out
motor 2 out (first to close)
motor 2 out
flashing light out + ve
flashing light out - ve
lamp / lock module – ve (black)
lamp / lock signal out (grey)
lamp / lock ve (red)
photocell power out
accessory power out
ground
photocell signal in (NC)
start signal in (NO)
ground
stop signal in (NC)
pedestrian access in (NO)
ground
antenna in
Содержание G915D